Toshiba RAS-10GAVP-E Service Manual page 86

Toshiba air condition service manual
Hide thumbs Also See for RAS-10GAVP-E:
Table of Contents

Advertisement

No.
Part name
Horizontal louver
Evaporator
(Heat exchanger)
Procedures
1) Remove shaft of the horizontal
louver from the back body.
(First remove the left shaft, and
then remove other shafts while
sliding the horizontal louver
leftward.)
1) Follow to the procedure in the item
2) Remove the pipe holder from the rear side of the main unit.
3) Remove two fixing screws at the left side of the end plate of the heat exchanger.
4) Remove the heat exchanger fixing holder
by removing the two fixing screws used to
secure it.
5) Remove right side of the end plate from
two fixing ribs while sliding slightly the
heat exchanger rightward.
– 86 –
Remarks
Slide the horizontal
louver leftward
ƒ
.
Disengage the claw
Screw
Screw
Pipe holder
Heat exchanger
fixing holder