Clean Operation Release - Toshiba RAS-10GAVP-E Service Manual

Toshiba air condition service manual
Hide thumbs Also See for RAS-10GAVP-E:
Table of Contents

Advertisement

Item
16. Clean operation
Setting the clean operation release
release
Setting the clean operation
Indoor P.C. board
Operation flow and applicable data, etc.
Add J04 of the indoor P.C. board assembly.
* This cancels the auto restart function.
Hold down the auto operation switch on the indoor unit
for at least 3 seconds but not more than 10 seconds.
The indoor unit's buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation release setting.
Cut J04 of the indoor P.C. board
* This step may be skipped if the auto restart function
is not required.
Hold down the auto operation switch on the indoor unit
for at least 3 seconds but not more than 10 seconds.
The indoor unit's buzzer emits three beeps, and
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation setting.
– 40 –
Description
* J04 will be near the MCU so take
steps to ensure that it will not be
exposed to excessive levels of
heat.
Also take care to avoid solder
bridging with the surrounding
components.
J04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents