Electrical work

8 Electrical work

8.1 Electrical installation

04.12.2015
Before carrying out electrical work:
 Warning! Risk of electric shock!
Install circuit breakers for personal protection.
 Any work on the electrical equipment of the machine shall only be per-
formed by professional electricians!
 For the power lines, use standard cables of sufficient capacity. Other-
wise there is a risk of short circuits, overheating or fire.
 When installing power lines, do not apply tension to the cables. Loos-
ened connections pose a risk of cables slipping from terminals or break-
ing; this can result in overheating or fire.
 Should it be necessary, disconnect all feed lines from the house fuse
box.
Follow the wiring diagram!
The installation must be performed by an accredited professional. He is also
responsible for the proper installation according to regulations and initial
commissioning.
For electrical installation, the regulations of VDE/EN as well as of EVU must
be observed.
For wiring, standard lines must be used.
Mains connection cable, if not connected to fixed installation:
Type H05VV-F.
Connection cables 230 / 400 V and remote cables / sensor cables must be
installed with separate cables.
Minimum diameter of connection cables 1.5 mm².
Attention: Terminals in connection terminal max. 4 mm². Vacant terminals
may not be used as support terminals for additional wiring.
Please note:
 All plug connections used in the heat pump control may not be con-
nected or disconnected under voltage – disconnect mains voltage.
 Before accessing connection terminals, all power supply circuits must
be interrupted.
 The relay circuit board (WWPR) may only be connected or removed by
professionals.
 Install and remove relay circuit board only in voltage-free state.
 All connections performed directly at the plug connections of the relay
circuit board must be established with flexible lines; if necessary, inter-
mediate terminals must be used.