Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field
Function
SYSTEM SETUP ( ✱ 20– ✱ 29)
∗ 20
INSTALLER CODE
✱ 21
QUICK ARM ENABLE
✱ 22
RF JAM OPTION
✱ 23
FORCED BYPASS
∗ 24
RF HOUSE ID CODE
✱ 26
CHIME BY ZONE
✱ 27
X–10 HOUSE CODE
✱ 28
ACCESS CODE FOR
4285/4286 PHONE MODULE
✱ 29 LONG RANGE RADIO OUTPUT
ZONE SOUNDS AND TIMING ( ✱ 31 – ✱ 39)
✱ 31
ONE AUDIBLE ALARM PER ZONE
✱ 32
FIRE ALARM SOUNDER TIMEOUT
✱ 33
ALARM SOUNDER TIMEOUT
✱ 34
EXIT DELAY
✱ 35
ENTRY DELAY #1 (zone type 01)
✱ 36
ENTRY DELAY #2 (zone type 02)
∗37
AUDIBLE EXIT WARNING
✱ 38
CONFIRMATION OF ARMING DING
✱ 39
POWER UP IN PREVIOUS STATE
DIALER PROGRAMMING ( ✱ 40 – ✱ 42)
Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for ' ✱ '; #+12 for '#'; #+13 for a 2-second pause.
∗40
PABX ACCESS CODE
∗41
PRIMARY PHONE No.
∗42
SECOND PHONE No.
352*5$00,1*)250
Data Entries
|
|
Part. 1 Part.2
[0]
Part. 1 Part. 2
|
Part. 1 Part. 2 Common
[0]
[0]
|
[00]
(Partition 1 only)
[0]
[0]
[0]
[1]
|
Part. 1 Part. 2
|
Part. 1 Part. 2
|
Part. 1 Part. 2
Part. 1 Part. 2
Part. 1 Part. 2
[1]
|
|
Enter up to 6 digits. If fewer than 6 digits are entered, exit by pressing [✶] and next
desired field number. To clear entries from field, press ✱40✱ .
|
|
|
|
|
|
|
Enter up to 20 digits; Do not fill unused spaces. If fewer than 20 digits entered, exit by pressing [✶] and
next desired field number. To clear entries, press ✱ 41 ✱ .
|
|
|
|
|
|
|
Enter up to 20 digits; Do not fill unused spaces. If fewer than 20 digits entered, exit by pressing [✶] and next
desired field number. To clear entries, press ✱ 42 ✱ .
Programmable Values
4 digits, 0–9
|
[6321]
0 = no; 1 = yes
[1,1]
0 = no RF Jam detection; 1 = send RF Jam report
UL: must be 1 if wireless devices are used
0 = none UL: must be "0"
[1,1]
1 = bypass open zones
00 = disable all wireless touchpad usage
|
|
01–31 = using 5827, 5827BD or 5804BD touchpad
[00,00,00]
0 = no; 1 = yes (select zones to chime on zone list 3,
using *81 Menu mode)
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
#14 = O, #15 = P UL: not for fire or UL installations
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
for " ✱ ", or # + 12 for "#".
UL: must be "00" for UL Commercial Burg. installations
0 = disable; 1 = enable
0 = no UL: must be "0"; 1 = yes
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be "1" for fire install.
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min;
4 = 16 min; UL: minimum "1" (4 min.)
00–99 = seconds of exit delay time for each partition
|
[60,60]
Common zones use same delay as partition 1.
00–99 = seconds of entry delay #1 time for each
|
[45,45]
partition; UL: 45 seconds max.
Common zones use same delay as partition 1.
00–99 = entry delay #2 time for each partition;
|
[90,90]
UL: 60 seconds max.
Common zones use same delay as partition 1.
0 = no; 1 = yes
[1,1]
0 = no; 1 = yes (wired touchpads and RF)
[0,0]
2 = yes, RF only
0 = no; 1 = yes UL: must be "1"
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 3 –
|
|
|
|
|
|
|
|

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Safewatch Pro 3000 and is the answer not in the manual?

Questions and answers

Ken
March 29, 2025

What is a check 90 trouble signal

1 comments:
Mr. Anderson
March 29, 2025

A CHECK 90 trouble signal on the ADT Safewatch Pro 3000 indicates that RF (radio frequency) interference may be impeding the operation of wireless sensors in the system. This may be caused by changes in the wireless environment that prevent the receiver from hearing a particular sensor. CALL FOR SERVICE if this occurs.