myC2-3
2XWLOODJHV 
-Tweezers , Gloves , Fixture Metal dome (252254450)
3UHOLPLQDU\ RSHUDWLRQ 
1.
Remove the battery (Proc sheet 0 01).
2.
Remove the lower housing of mobile (Proc sheet 1 01).
3.
Remove MMI board (Proc sheet 1 07).
5HPRYDO SURFHGXUH 
This procedure must be performed by a technician with gloves.
1. Take care of the component metal dome (1) with a tweezers.
2. Put the board upside down (2), take the metal dome (3).
3. Carefully check there is no spot cleft on the board (4).
3ODFHPHQW SURFHGXUH 
:DUQLQJ  The metal dome is not reusable, it must be replaced by a new metal dome.
1. Position the MMI board in the tool of metal dome (252254450.)
2. Position the metal dome on the MMI board.
3. Take off the board of the tool , put the board upside down and puss part (5)
)XUWKHU RSHUDWLRQ 
1. Place the keyboard ( Proc sheet 1 04)
2. Place the board MMI (Proc sheet 1 07)
3. Place the lower housing of mobile (Proc sheet 1 01).
4. Place of the battery (Proc sheet 0 01)

Contents
5HPRYH DQG SODFH PHWDO GRPH


REF MTB DTS 8- Indice B - February 21 2006
Proc sheet 1 08
Risk of the procédure :
Damage the component of MMI board

Procedure
Proc 0 01
Proc 1 01
Proc 1 02
Proc 1 03
1/1
Proc 1 04
Proc 1 05
Proc 1 06
Proc 1 07
Proc 1 08
Proc 1 09
Proc 1 10
Proc 1 11
Proc 1 12
Proc 2 02
Proc 3 01
Proc 3 02
Proc 4 01
Symptom
Symp 01
Symp 02
Symp 03
Symp 04
Symp 05
Symp 06
Symp 07
Symp 08
Symp 10
Test
Test 01
Test 02
Test 03
Test 04
Test 05
Test 06

Page 5-15

Advertisement

Table of Contents
loading

Table of Contents