Overview; Technical Specifications; Instructions For Use - Flex CA 18.0 Operating Manual

Hide thumbs Also See for CA 18.0:
Table of Contents

Advertisement

Available languages

Available languages

440.183_Ladegerät CA 10.8.book Seite 8 Montag, 8. Februar 2016 3:00 15
Intended use
The battery charger CA 10.8 is designed for
charging FLEX batteries of types
– AP 10.8/2.5,
– AP 10.8/4.0 and
– AP 10.8/6.0.
The battery voltage must match the battery
charging voltage of the charger. Otherwise
there is danger of fire and explosion.
Safety instructions for the battery
charger
 Keep the battery charger away from rain or
moisture. Penetration of water in the
battery charger increases the risk of an
electric shock.
 Keep the battery charger clean.
Contamination can lead to danger of an
electric shock.
 Before each use, check the battery
charger, cable and plug. If damage is
detected, do not use the battery charger.
Never open the battery charger yourself.
Have repairs performed only by a qualified
technician and only using original spare
parts. Damaged battery chargers, cables
and plugs increase the risk of an electric
shock.
 In case of damage and improper use of the
battery, vapours may be emitted. Ventilate
the area and seek medical help in case of
complaints. The vapours can irritate the
respiratory system.
 Do not place any objects on the battery
charger and do not place the battery
charger on soft surfaces.
There is a risk of fire.
 Always check that the mains voltage
matches the voltage indicated on the
rating plate of the battery charger.
8

Overview

1
Slot for battery
2
Contacts
3
LED fault message (red)
4
LED charge status (green)
5
Ventilation slots
6
Power cord with plug

Technical specifications

Device
Input voltage
V~/Hz 220-240/
Charging voltage
V–
Charging time (depen-
min
ding on charge state)
min
min
Operating temperature °C
Weight (without battery) kg
Protection class

Instructions for use

CAUTION!
Never charge batteries at temperatures
below 0 °C or above 40 °C.
Do not charge batteries in an
environment which has high air humidity
or at a high ambient temperature.
Do not cover batteries and/or the battery
charger during the charging process.
CA 10.8
Battery charger
CA 10.8
50-60
12.6
2.5 Ah: 40
4.0 Ah: 55
6.0 Ah: 85
0–40
0.52
II /

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ca 10.8