Planet Networking & Communication IPM-16120 User Manual

Ip-based 16-port metered

Advertisement

Quick Links

IP-based 16-port Metered
Power Distribution Unit
IPM-16120

Advertisement

Table of Contents
loading

Summary of Contents for Planet Networking & Communication IPM-16120

  • Page 1 IP-based 16-port Metered Power Distribution Unit IPM-16120...
  • Page 2 IP-based 16-port Metered Power Distribution Unit IPM-16120 Copyright Copyright  2016 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
  • Page 3 Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision User’s Manual of PLANET IP-based 16-port Metered Power Distribution Unit Model: IPM-16120 Rev: 1.00 (June, 2016) Part No. EM-IPM-16120_v1.0...
  • Page 4: Table Of Contents

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Table of Contents Chapter 1. Product Introduction ..................... 6 1.1 Package Contents ......................6 1.2 Overview ........................6 1.3 Features ........................9 1.4 Specifications ......................10 Chapter 2. Hardware Interface .................... 12 2.1 Physical Descriptions ....................12 2.2 Installation Precautions ....................
  • Page 5 IP-based 16-port Metered Power Distribution Unit IPM-16120 Appendix A: Reset to Default via Navigation Button .............. 40 Appendix B: HTTP Message API Example ................41...
  • Page 6: Chapter 1 Product Introduction

    1.2 Overview High Voltage Power Distribution Unit with Digital Load Meter PLANET IPM-16120 is a 16-port IP Power Management device that provides premium power protection for your professional workstations and connected devices. With the innovative IP-based technology, PLANET has made the traditional power management equipment into true networking...
  • Page 7 IP-based 16-port Metered Power Distribution Unit IPM-16120 Vertical Mounting Any devices can be easily mounted vertically in racks or enclosures and occupy zero U of valuable rack space, which allows more equipment in the rack. Electric Current Monitored on Display The aggregate current draw per rack PDU is displayed on the unit via a digital display.
  • Page 8 IP-based 16-port Metered Power Distribution Unit IPM-16120 and Telnet. They allow users to access, configure, and manage units from remote locations to save valuable time. Overload Protection 16-amp circuit breaker prevents dangerous circuit overloads that could damage equipment. The PDU features a built-in circuit breaker and reset switch, ensuring dependable performance of vital equipment.
  • Page 9: Features

    IP-based 16-port Metered Power Distribution Unit IPM-16120 1.3 Features  Hardware ■ Zero U rack-mount size design ■ IEC outlet models ■ 16 power outlets that support real-time current image monitoring ■ 10ft (3m) power cord ■ Hot-swap IP-module without power shutdown ■...
  • Page 10: Specifications

    IP-based 16-port Metered Power Distribution Unit IPM-16120 1.4 Specifications Product IPM-16120 Hardware Specifications Output Power Port Input Power Port Buzzer Breaker 1 x 16A Network Connector 1 RJ45 port for 10/100BASE-TX Button Five-sided button Alarm Lights remaining lit: Alarm has occurred...
  • Page 11 IP-based 16-port Metered Power Distribution Unit IPM-16120 System Unit Operating Temperature -5 ~ 45 degrees C Operating Humidity 5 ~ 95% 0 ~ 4500 meters Operating Altitude Dimensions (W x D x H) 748 x 43 x 43 mm 1.7kg...
  • Page 12: Chapter 2 Hardware Interface

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Chapter 2 Hardware Interface 2.1 Physical Descriptions Dimensions (W x D x H) 748 x 43 x 43 mm 1.7kg (gross weight) Weight Front Panel RJ45 Port Enable user to configure the IP Metered PDU through a LAN or WAN.
  • Page 13 IP-based 16-port Metered Power Distribution Unit IPM-16120 Panel Operation The first mode of LCD is total current, switching with the five-sided button down to show the regular sequence of current info, max. current, inner temp. and network info as shown below: ...
  • Page 14: Installation Precautions

    IP-based 16-port Metered Power Distribution Unit IPM-16120  When the LCD menu shows network info, hold the five-sided button for 10 seconds until two beeps sound to enter reset mode. 2.2 Installation Precautions  Please set the maximum power-off protection allowed by power circuit as per the rated current information indicated on the device with reference to the local state rules, safety procedures and disconnector deviation.
  • Page 15: Initial Utility Installation

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Please make sure all the units connected are powered off before the installation of the device and take other necessary precautions during the installation. 2.4 Initial Utility Installation PLANET “IP Search” is a software utility used to search the IP Metered PDU product on a network quickly and with ease.
  • Page 16 IP-based 16-port Metered Power Distribution Unit IPM-16120 Step 2: Please press the “Refresh” button to find out your IP Metered PDU. 1. Before searching the IP, please make sure your PC is in the same IP segment as control gateway.
  • Page 17: Chapter 3 Quick Setup

    3.2 Setup Wizard When you use the IPM-16120 for the first time, after it is connected to the Internet, browser would pop up Setup Wizard asking you to provide language, account, password, network and time zone. Step 1: Language Selection Select your language currently available in English, Traditional Chinese and Simplified Chinese, and press Next to continue.
  • Page 18 IP-based 16-port Metered Power Distribution Unit IPM-16120 Step 2: Account Setting This menu is for setting the admin account and password of the device. Press Next to continue. Step 3: Host Setting The product is assigned dynamically (DHCP). To specify a fixed IP address, please fill in IP Address, Subnet Mask and Gateway.
  • Page 19 IP-based 16-port Metered Power Distribution Unit IPM-16120 Step 5: Web Server Https can help protect streaming data transmission over the internal on the higher security level. You can select the connection type. "Https" means user cannot connect the camera via Http protocol. The Https path will be: "https://(IP address)/".
  • Page 20 IP-based 16-port Metered Power Distribution Unit IPM-16120 Step 9: Daylight Saving Time Set the Daylight saving time from Sunday to Saturday. Press Next to continue. Step 10: General Setting You may set up operational overtime in this section. Press Finish to save all settings.
  • Page 21: Chapter 4 Web-Based Management

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Chapter 4 Web-based Management This section provides instructions about how to use the web interface to configure and control the IP Power Manager remotely. 4.1 Monitor After a successful login, the web page will display the following operation menu where each part is...
  • Page 22: System

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Displays the consumption power value of the current input Power (watt) power. Displays the consumption watt-hour of the device since Kilowatt Hour (kWh) the last zeroing. Inputs the current value of the overload power, alarms will...
  • Page 23 IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description Enabled DHCP Use checkbox to enable DHCP. It will assign IP address. Host Assign the Network IP address for the power switch. Set up the subnet mask info of this equipment.
  • Page 24: Email Server

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description Disable ICMP When Disable ICMP Response check box is selected, the examination will not be responded. Response 4.2.2 Email Server When there is a triggered warning from the setup of this PDU, this device will send out alert message to the preset email accounts.
  • Page 25: Sms Server

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description this function is normal. 4.2.3 SMS Server In this section, user can set up the warning message and info to the SMS server. The protocol here is supported by many SMS suppliers’ (ISP) API. System will send out account, password, time, and related info via HTTP to the SMS server of ISP supplier or preset SMS server.
  • Page 26: Snmp

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description @@DEVICENAME@@ The device name to show as sending a message. @@ACCOUNT@@ The account to send the message. The password to send the message. @@PASSWORD@@ @@GSMNUM@@ The number to send the message.
  • Page 27 IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description SNMP v1/v2 Enable Enable SNMP v1/v2. SNMP Port Set the destination port. Default is 161. Read Community Key-in passwords for the Community Name field. Default is public. SNMP Writing Select the checkbox to enable SNMP Write-in.
  • Page 28: Syslog

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description sysName The name displayed on SNMPAgent. sysContact The contact displayed on SNMPAgent. The location displayed on SNMPAgent. sysLocation Parameters Description Host The Host IP address of SNMP Trap. SNMP Trap Port The phase connects to SNMP Trap.
  • Page 29: Peripheral Parameters

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description normal. 4.2.6 Peripheral Parameters This menu is mainly for setting current, tolerance ranges of temperature and humidity, power statistics and probe as well as the panel operating, etc. Parameters Description You may set up threshold current to avoid floating power triggered Released Load warning reaction.
  • Page 30: Other

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description (Range) warning reaction. The warning will be dismissed by system when temp is lower than threshold temp. Parameters Description You may set up threshold current to avoid floating power triggered Direction warning reaction.
  • Page 31: Firewall

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description down list: YYYY/MM/DD/HH/MM/SS MM/DD/YYYY/HH/MM/SS DD/MM/YYYY/HH/MM/SS MQTT Host Enter MQTT Host IP. MQTT Port Enter Connect Port for MQTT. Default is 1883. Parameters Description IP Lock-up Period The period of such IP has been locked up.
  • Page 32: Mac Filter

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description After keying in permitted IP section, please click ADD to implement Allowed IP Section this action. To delete a specific IP address, please click “X”. 4.3.2 MAC filter This menu is mainly for setting of Network MAC Address having access to this device.
  • Page 33: Basic Info

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description Modify Modify the previous setting. Operation of Alarm. Click Delete icon: browser will pop up a Confirmation of delete Delete window. Click Confirm: this Account cannot be utilized any longer. 4.4.1 Basic Info To set up account, password and user type.
  • Page 34: Email

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description  Administrator: Administrator can manage the whole network. 4.4.2 Email System would send email when alarm occurs. Parameters Description Check to open email alarm system informed by email. Enable Alert ‘Send’ To Enter the mail address of Receiver.
  • Page 35 IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description Check to open email alarm system informed by SMS. Enable Alert Informed by short message, please fill out the right cellphone Cellphone number. Use the checkbox to enable the setting. The system will follow the Parameter warning method you choose.
  • Page 36: Time

    IP-based 16-port Metered Power Distribution Unit IPM-16120 4.5 Time You can set up the time server on this page. Parameters Description Date and time of the system. Device Time Time You may either scroll down to select Sync with computer or Manual Synchronization Setting.
  • Page 37: Chart

    IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description Enable daylight Set the Daylight saving time from Sunday to Saturday saving time 4.6 4.6 Chart This menu is mainly for query infeed, device temperature and statistic data. Parameters Description Category You may either scroll down to select infeed or device temperature.
  • Page 38: Event

    IP-based 16-port Metered Power Distribution Unit IPM-16120 4.7 Event The web page supports to query the recent 200 logs, including the time, types and reasons of such logs. Parameters Description Refresh Click the Refresh button to refresh the screen. Click teh Download button to save the event log information. The Download event log is saved in .txt format.
  • Page 39 IP-based 16-port Metered Power Distribution Unit IPM-16120 Parameters Description To update the firmware online, click “Browse…” to select the Upload firmware firmware. Then click “Upgrade” to proceed. Upload configuration Upgrade from previous saved setting. Download Download the current setting to PC.
  • Page 40 IP-based 16-port Metered Power Distribution Unit IPM-16120 Appendix A: Resetting to Default via Navigation Button Users who forget the network account and password of the product can press "Reset" to recover to the factory default values, and the device will be rebooted at the same time.
  • Page 41 IP-based 16-port Metered Power Distribution Unit IPM-16120 Appendix B: HTTP Message API Example A Message API example of a message service provider is given below. The transmission mode is Get in TTP protocol, and the URL format is as follows: http://SMLWsip/httpSMLWs.php?Tag=Value&Tag=Value&Tag=Value…...
  • Page 42 IP-based 16-port Metered Power Distribution Unit IPM-16120 Press the icon on the left side of the blank to see message format for reference. Parameters Description @@DEVICENAME@@ The device name to show as sending a message. @@ACCOUNT@@ The account to send the message.
  • Page 43 IP-based 16-port Metered Power Distribution Unit IPM-16120 Message format Description Company code (depid=xxxxxx) & Required User's Account Required (account=@@ACCOUNT@@)& User's password Required (password=@@PASSWORD@@)& Cellphone number Required (dstaddr=@@GSMLWNUM@@)& Device IP & Message content This format is changeable with the content. (IPMbody=@@IP@@,@@MSG@@)

Table of Contents