  • Page 1 MVME721X RTM Installation and Use P/N: 6806800M42D April 2015...
  • Page 2 Artesyn reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or changes.
  • Page 3: Table Of Contents

    FRU Serial EEPROM ..............49 MVME721X RTM Installation and Use (6806800M42D)
  • Page 4 Related Documentation ............. . . 51 Artesyn Embedded Technologies - Embedded Computing Documentation ....51...
  • Page 5 Front Panel LEDs ............. . . 48 Table A-1 Artesyn Embedded Technologies - Embedded Computing Publications ....51 MVME721X RTM Installation and Use (6806800M42D)
  • Page 6 List of Tables MVME721X RTM Installation and Use (6806800M42D)
  • Page 7 Rear Panel Connectors and LEDs ......... . 41 MVME721X RTM Installation and Use (6806800M42D)
  • Page 8 List of Figures MVME721X RTM Installation and Use (6806800M42D)
  • Page 9: About This Manual

    MVME721X RTM. The user must be a professional engineer in the server device field, who has been trained and is able to identify danger levels when operating the device.
  • Page 10 Used for references and for table and figure descriptions File > Exit Notation for selecting a submenu <text> Notation for variables and keys [text] Notation for software buttons to click on the screen and parameter description MVME721X RTM Installation and Use (6806800M42D)
  • Page 11 Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury Indicates a property damage message No danger encountered. Pay attention to important information MVME721X RTM Installation and Use (6806800M42D)
  • Page 12 Updated drawings of IEEE and Scanbe handles and updated RTM installation and removal procedures in Chapter 2, RTM Installation and Removal, on page 28. Updated information on Table "Environmental Conditions" on page 6806800M42D April 2015 Re-branded to Artesyn template. MVME721X RTM Installation and Use (6806800M42D)
  • Page 13: Safety Notes

    Artesyn intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
  • Page 14 Changes or modifications not expressly approved by Artesyn could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements.
  • Page 15 Therefore, carefully inspect the RTM and the backplane for both pin and component integrity before installation. Artesyn and our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the blades/RTMs prior to leaving the factory. Bent pins caused by improper installation or by inserting blades with damaged connectors could void the Artesyn warranty for the backplane or blades.
  • Page 16 Safety Notes MVME721X RTM Installation and Use (6806800M42D)
  • Page 17: Sicherheitshinweise

    Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht garantieren. Falls Sie weitere Informationen benötigen sollten, wenden Sie sich bitte an die für Sie zuständige Geschäftsstelle von Artesyn. Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf ausschließlich für Anwendungen in der Telekommunikationsindustrie und im Zusammenhang...
  • Page 18 Sicherheitshinweise Das Produkt wurde in einem Artesyn Standard system getestet. Es erfüllt die für digitale Geräte der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen angemessenen Schutz vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie Industriegebieten...
  • Page 19 Pins und Stecker von Blades/RTMs vor dem Verlassen der Produktionsstätte in einwandfreiem Zustand befinden. Verbogene Pins, verursacht durch fehlerhafte Installation oder durch Installation von Blades/RTMs mit beschädigten Steckern kann die durch Artesyn gewährte Garantie für Blades und Backplanes erlöschen lassen.
  • Page 20 Sicherheitshinweise Umweltschutz Entsorgen Sie alte Batterien und/oder Blades/Systemkomponenten/RTMs stets gemäß der in Ihrem Land gültigen Gesetzgebung. MVME721X RTM Installation and Use (6806800M42D)
  • Page 21: Introduction

    The MVME721X Rear Transition Module (RTM) of the blade (hereinafter referred as MVME721X-RTM) must work with MVME721X blades. The MVME721X RTM is for I/O routing through the rear of a compact VMEbus chassis. It connects directly to the VME backplane in chassis with an 80 mm deep rear transition area. The MVME721X RTM is designed for use with the MVME7100, MVME2500, iVME7210, and MVME4100.
  • Page 22: Rear Transition Module Layout

    Introduction Rear Transition Module Layout The following illustration shows the component layout and connectors on the MVME721X RTM. Figure 1-2 Component Layout S1 SMT Switch MVME721X RTM Installation and Use (6806800M42D)
  • Page 23: Standard Compliances

    Standard Description UL 60950-1 Safety Requirements (legal) EN 60950-1 IEC 60950-1 CAN/CSA C22.2 No 60950-1 CISPR 22 EMC requirements (legal) on system level (predefined Artesyn CISPR 24 system) EN 55022 EN 55024 FCC Part 15 Industry Canada ICES-003 VCCI Japan...
  • Page 24: Ordering Information

    As of the printing date of this manual, this product has the following variants: Table 1-3 Available RTM Variants Order Number Description IEEE Rear Transition Module MVME7216E-101 MVME721ET-101 Rear Transition Module IEEE handle - Extended Temperature MVME721ET-102 RTM SCANBE handle - Extended Temperature MVME7216E-102 RTM SCANBE handle MVME721X RTM Installation and Use (6806800M42D)
  • Page 25: Hardware Preparation And Installation

    Verify that you have received all items of your shipment: MVME721X RTM  One printed copy of Quick Start Guide  One printed copy of Safety Notes Summary  Any other items ordered  MVME721X RTM Installation and Use (6806800M42D)
  • Page 26: Requirements

    PIM modules, with more restrictive environmental requirements. Operating temperatures refer to the temperature of the air circulating around the blade  and not to the actual component temperature. MVME721X RTM Installation and Use (6806800M42D)
  • Page 27: Table 2-1 Environmental Conditions

    +/-0.5° C/min according to NEBS Standard GR-63-CORE Relative humidity 5% to 90% non-condensing 5% to 90% non-condensing Vibration 1 G sine sweep, 5 - 200 Hz, with a sweep rate of 0.25 octaves/minute in three mutually perpendicular axis MVME721X RTM Installation and Use (6806800M42D)
  • Page 28: Rtm Installation And Removal

    2.3.1 PMC I/O Module (PIM) Installation NOTE: If a PMC I/O Module (PIM) has already been installed on the MVME721X RTM, or if you are installing an RTM as it has been shipped from the factory, disregard this procedure. For PIM installation, perform the following steps: 1.
  • Page 29: Figure 2-1 Installing The Pim

    RTM into the PIM front bezel and rear standoffs. Tighten the screws. For more information on PIM connectors and its signals, see PMC Input/Output Module (PIM) Connectors (J10/J14). Figure 2-1 Installing the PIM PIM Alignment MVME721X RTM Installation and Use (6806800M42D)
  • Page 30: Installing The Rtm

    Remove the filler panel(s) from the appropriate card slot(s) at the rear of the chassis (if the chassis has a rear card cage). Install the top and bottom edge of the RTM into the rear guides of the chassis. MVME721X RTM Installation and Use (6806800M42D)
  • Page 31: Ieee Handles

    Hardware Preparation and Installation Ensure that the IEEE handles are in the outward position. Figure 2-2 IEEE Handles Press the buttons to unlock the handles. MVME721X RTM Installation and Use (6806800M42D)
  • Page 32: Ieee Handles

    Hardware Preparation and Installation Slide the RTM into the chassis until resistance is felt. Figure 2-3 IEEE Handles MVME721X RTM Installation and Use (6806800M42D)
  • Page 33: Ieee Handles

    Hardware Preparation and Installation Simultaneously move the handles in an inward direction to lock the RTM to the chassis. Figure 2-4 IEEE Handles Press inward to lock. MVME721X RTM Installation and Use (6806800M42D)
  • Page 34: Ieee Handles

    Verify that the RTM is properly seated and secure it to the chassis using the two screws located adjacent to the IEEE handles. Figure 2-5 IEEE Handles Captive Screw Connect the appropriate cables to the RTM. MVME721X RTM Installation and Use (6806800M42D)
  • Page 35 Remove the filler panel(s) from the appropriate card slot(s) at the rear of the chassis (if the chassis has a rear card cage). Install the top and bottom edge of the RTM into the rear guides of the chassis. MVME721X RTM Installation and Use (6806800M42D)
  • Page 36: Scanbe Handles

    Hardware Preparation and Installation Ensure that the Scanbe handles are in the outward position. Figure 2-6 Scanbe Handles Slide the RTM into the chassis until resistance is felt. MVME721X RTM Installation and Use (6806800M42D)
  • Page 37: Removing The Rtm

    7. Slide the RTM from the rear guides of the chassis. 8. Carefully remove the RTM from the chassis and store in an anti-static envelope. 9. Install the filler panel into the appropriate slots at the rear of the chassis. MVME721X RTM Installation and Use (6806800M42D)
  • Page 38 Hardware Preparation and Installation MVME721X RTM Installation and Use (6806800M42D)
  • Page 39: Controls, Leds, And Connectors

    FRU Serial EEPROM  SEEPROM Address Switch, S1 A 4-position SMT configuration switch is located on the MVME721X RTM to set the device address of the RTM serial EEPROM device. The switch settings are defined in the next table. Figure 3-1...
  • Page 40 Controls, LEDs, and Connectors Table 3-2 Switch Settings and Device Addresses (continued) A(2-0) Device Address $AA (default) MVME721X RTM Installation and Use (6806800M42D)
  • Page 41: Rear Panel Connectors And Leds

    Controls, LEDs, and Connectors Rear Panel Connectors and LEDs The MVME721X RTM provides the following connectors and LEDs. Figure 3-2 Rear Panel Connectors and LEDs COM2 COM3 COM4 COM5 Enet 1 SPEED G Enet 2 SPEED PMC Site MVME721X RTM Installation and Use (6806800M42D)
  • Page 42: Rear Panel Connectors

    The pin assignments for the J1 and J2 connectors are as follows: Table 3-4 J1 and J2 Connector Pin Assignments Pin Name Signal Description Pin Name Signal Description E2_0P SP4_RTS E2_0N E2_1P SP4_TX E2_1N SP4_RX E2_2P E2_2N SP4_CTS E2_3P E2_3N E1_0P SP3_RTS E1_0N E1_1P MVME721X RTM Installation and Use (6806800M42D)
  • Page 43: Table

    Controls, LEDs, and Connectors Table 3-4 J1 and J2 Connector Pin Assignments (continued) Pin Name Signal Description Pin Name Signal Description SP3_TX E1_1N SP3_RX E1_2P E1_2N SP3_CTS E1_3P E1_3N SP2_RTS SP2_TX SP2_RX SP2_CTS SP1_RTS SP1_TX SP1_RX SP1_CTS MVME721X RTM Installation and Use (6806800M42D)
  • Page 44: Pmc Input/Output Module (Pim) Connectors (J10/J14)

    PMC Input/Output Module (PIM) Connectors (J10/J14) The pin assignments for the J10 and J14 connectors are as follows: Table 3-5 J10 Connector Pin Assignments PMC (J10) Pin Name Signal Description Pin Name Signal Description +3.3V +3.3V MVME721X RTM Installation and Use (6806800M42D)
  • Page 45: Table 3-6 J14 Connector Pin Assignments

    Pin Name Signal Description Pin Name Signal Description PMC_IO_1 PMC_IO_33 PMC_IO_2 PMC_IO_34 PMC_IO_3 PMC_IO_35 PMC_IO_4 PMC_IO_36 PMC_IO_5 PMC_IO_37 PMC_IO_6 PMC_IO_38 PMC_IO_7 PMC_IO_39 PMC_IO_8 PMC_IO_40 PMC_IO_9 PMC_IO_41 PMC_IO_10 PMC_IO_42 PMC_IO_11 PMC_IO_43 PMC_IO_12 PMC_IO_44 PMC_IO_13 PMC_IO_45 MVME721X RTM Installation and Use (6806800M42D)
  • Page 46 There are no host I/O signals on this connector. The front board routes the PIM from J14 of PMC Slot 1 to VME P2 rows A and C. The MVME721X RTM routes these signals (pin-for- pin) from VME P2 to PMC I/O module connector J14.
  • Page 47: Vme Backplane P2 Connector

    PMC IO 38 PMC IO 37 Serial 3 TX PMC IO 40 PMC IO 39 E2_4 - PMC IO 42 PMC IO 41 E2_4 + Serial 3 CTS PMC IO 44 PMC IO 43 MVME721X RTM Installation and Use (6806800M42D)
  • Page 48: Leds

    1000 BASE-T operation GENET1 Front panel No activity Integrated Blinking Green Activity proportional to bandwidth RJ45 LED utilization GENET2 Front panel No link Integrated RJ45 SPEED Amber 10/100BASE-T operation LED (Left) Green 1000BASE-T operation MVME721X RTM Installation and Use (6806800M42D)
  • Page 49: Fru Serial Eeprom

    FRU Serial EEPROM The MVME721X RTM provides a 64 kB (8192 x 8bits) I2C serial EEPROM. This is a 24C64D type device. The EEPROM resides at I2C address 0xA0 (default), this address can be changed by configuring the SW1 switch. Care must be taken on configuring this switch, it may cause address conflict with I2C device on the front board.
  • Page 50 Controls, LEDs, and Connectors MVME721X RTM Installation and Use (6806800M42D)
  • Page 51: Table A-1 Artesyn Embedded Technologies - Embedded Computing Publications

    The publications listed below are referenced in this manual. You can obtain electronic copies of Artesyn Embedded Technologies - Embedded Computing publications by contacting your local Artesyn sales office. For released products, you can also visit our Web site for the latest copies of our product documentation.
  • Page 52 Related Documentation MVME721X RTM Installation and Use (6806800M42D)
  • Page 54 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other product or service names are the property of their respective owners. © 2015 Artesyn Embedded Technologies, Inc.

Table of Contents