Reordering Multiple Defined Arrays Across Previously Used Bays In Two Storage Enclosures; Subsystem Management Logical/Physical - IBM System Storage DCS Series Installation And Migration Manual

With gen2 controllers, hard disk drive and storage enclosure
Table of Contents

Advertisement

v Using the Export function is equivalent to placing the array in Offline state. See
v When you install the first drive in its new location within the storage subsystem,
Figure 5. Reordering multiple defined arrays across previously used bays in two storage
enclosures
To reorder drives that make up arrays across different drive bays in the same
storage subsystem configuration, complete the following steps:
1. Start the DS Storage Manager Client program and open the Storage Subsystem
2. Mark the drives in the arrays.
3. Export the arrays that you plan to move.
4. Unlatch the drives. Wait at least 2 minutes for each drive to spin down.
5. Remove the drives from the bays.
6.
Figure 6. Subsystem Management Logical/Physical View of missing logical drives
22
IBM System Storage DCS Series with Gen2 controllers Hard Disk Drive and Storage Enclosure Installation and Migration
Guide
"Step 3: Placing drives offline" on page 17 for details on exporting an array.
the Array icon appears with an arrow but does not change to Online state
automatically. You must use the Import function to place the array in Online
state.
1 2 3
1 2 A
A B
3 B
Before
After
Management window (for the storage subsystem whose drives you are
reordering).
Note: Figure 6 shows the array status as missing an array in subsystem
because the array was not exported before the drives that made up the array
were removed from the storage subsystem.
Ensure that all of the drives that made up the arrays are removed from their
bays.
Empty slot
Drive associated with array
Drive associated with array