Blower Motor Installation - Thermador HPCN36WS Installation Instructions Manual

Professional chimney wall hoods
Hide thumbs Also See for HPCN36WS:
Table of Contents

Advertisement

Available languages

Available languages

Blower Motor Installation

Blower and Circuit Breaker Ratings
Blower
SKU
Remote
VTR630
120
Remote
VTR1030
120
Remote
VTR1330
120
In-line
VTI610
120
In-line
VTI1010
120
Integral
VTN630
120
Integral
VTN1090
120
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the
Ventilation Planning Guide.
NOTE: Cutting the plug of the blower will void the
warranty or eligibility for return or exchange.
All blower models are sold separately. Use only
Thermador blowers with these ventilation hoods. See the
Ventilation Planning Guide
Contact Customer Service for additional options.
All hood models are rated for 120V AC installed with a
blower listed in the table above, using a 15 amp
dedicated circuit breaker. The VTR1330 blower in
conjunction with a PHxxGWS requires a 20 amp circuit
breaker.
Blower selection will vary based on the volume of air that
needs moved and the length and location of the duct run.
For long duct runs with multiple turns and bends, consider
using a more powerful blower. For the most efficient air
flow exhaust, use a straight run or as few elbows as
possible (refer to "Ductwork Preparation").
Breaker
Voltage
Current
Amp
4.2
15
5.7
15
8.5
15 / 20
4.2
15
5.7
15
4.2
15
5.4
15
for recommended blowers.
Integral blower installation
Integral Blower models are integrated into the hood at the
time of installation. Integral Blowers should be installed
after the hood is mounted to the wall.
For complete installation instructions see the instructions
supplied with the blower unit.
inches (mm)
18⅞"
18⅞"
(473)
(473)
8¼"
8¼"
(208)
(208)
1. The blower is attached to the hood using weld studs
on the mounting plate. Guide the motor mounting
plate over the studs.
2. Attach four (4) nuts (included with hood) to the weld
studs. Tighten nuts with a 11/32'' nut driver to secure
the blower to the hood.
10⅞"
10⅞"
(275)
(275)
13⅛"
13⅛"
(335)
(335)
Page. 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpcn48ws