Reading Version Number; Reset Command; Parameter Setting Command - Ebyte E32-DTU User Manual

Hide thumbs Also See for E32-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd

7.3 Reading version number

Instruction format
C3+C3+C3

7.4 Reset command

Instruction format
C4+C4+C4

7.5 Parameter setting command

Working parameters can be C0 or C2 co mmand, the difference is: the C0 co mmand will write parameters to the module
FLASH, power down save.
C2 co mmand is a temporary mod ification instruction, and the parameters will not be power-off to save, wh ich is suitable
for the occasion of frequent modification of working parameters. For example: C0 00 00 18 03 44.
No.
Item
0
HEAD
1
NC
2
NC
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
In the sleep mode (M 0=1, M 1=1),
The user issues a command to the module serial port (HEX format) : C3, C3,
The module returns the current configuration parameters, such as C3 64 xx yy.
Here, 64 refers to the module model (E64 series), xx is the version number, and yy refers to
other features of the module.
In sleep mode, the user issues a command to the module serial port (HEX format) : C4, C4,
C4, and the module will generate a reset.
During the reset process, the module conducted self-inspection and AUX output low level.
After the reset, AUX output high level and the module began to work normally. At this
point, you can switch modes or issue the next instruction.
Description
Fix 0xC0 or 0xC2 to indicate that this frame data is a
control command
Reserved
Reserved
Description
Description
It must be 0xC0 or C2
C0: the parameters set will be saved
after power failure.
C2: the parameters set will not be
saved after power off
E32-DTU (433NW20) user manual
Remark
13

Advertisement

Table of Contents
loading

Table of Contents