Command Format; Default Parameters; Reading Operating Parameters - Ebyte E32-DTU User Manual

Hide thumbs Also See for E32-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd

7 Command format

In sleep mode(Mode 3:M1=off, M0=off), it supports below instructions on list.
(Only support 9600 and 8N1 format when setting)
No.
1
2
3
4
5

7.1 Default parameters

Type
M odel
E64-DTU (433NW20)

7.2 Reading operating parameters

Instruction format
C1+C1+C1
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
Instruction
format
C0+working
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
parameters
must be sent in succession, ( Save the parameters when power-down ).
Hexadecimal format sends three C1, the module returns saved parameters, must be sent
C1+C1+C1
continuously.
Send C2+5 bytes in hexadecimal format: 6 bytes of working parameters, must be sent
C2+working
continuously (power off without saving)
parameters
Hexadecimal format sent three C3, the module return version information, must be sent
C3+C3+C3
continuously.
Hexadecimal format sent three C4, the module will produce a reset, must be sent
C4+C4+C4
continuously.
Default parameter values:C0 00 00 1C 20 64
The
Slave
network
address
number
0x00
0x00
In sleep mode(M 0=1,M 1=1),
User gives the module instruction (HEX format): C1 C1 C1,
M odule returns the present configuration parameters.
For example, C0 00 00 1C 20 64.
Illustration
Air data rate
Baud rate
8kbps
9600
Description
E32-DTU (433NW20) user manual
Transmitting
Parity
Power
8N1
100mW
FEC
on
12

Advertisement

Table of Contents
loading

Table of Contents