Technical Specifications
Connection data at X101
Power supply
Voltage POE
Power consumption
Display
Ringing sound pressure level
Housing (height x width x depth)
Weight
Operating position
Receiver
Microphone
Receiver inset
Connection X101
Dimensions Connecting cable / Cable entry
Cable glands
Blind plugs
Connecting cable diameter
Connection potential compensation
mbient temperature range and explosion protection
Type of protection
Operating ambient temperature range -20°C Ta +55°C
Storage and transport temperature
Housing degree of protection
Labelling
Firma
Type
DEKRA
CE 0158
IECEx
6
Power over Ethernet according to IEEE 802.3af
48 VDC (min. 44 V, max. 61 V)
3.5 W
128 x 64 pixels
max. approx. 95 dB (A) at 1 m
293 x 191 x 128
approx. 2,300 g
Table or vertical wall mounting
Electret-foil microphone
Dynamic receiver inset with magnetic field generator
(10/100 Mbit/s) LAN cable with 8 conductors
AWG 22 to 24 for solid conductors, or
AWG 24 for multi-wired conductors
M20 x 1,5
M20 x 1,5 / M12 x 1,5
6 – 13 mm
1,5 – 4 mm
2
Ex nA ic IIC T5 Gc
Ex tc ic IIIC T80°C Dc
-25°C Ta +70°C
IP65
FHF Funke+Huster Fernsig GmbH
FernTel IP Z2
BVS 08 ATEX E 022
II 3 G Ex nA ic IIC T5 Gc
II 3 D Ex tc ic IIIC T80°C Dc
-20°C Ta +55°C
IP65 U
= 61 VDC; U
m
Ex nA ic IIC T5 Gc
Ex tc ic IIIC T80°C Dc
IECEx BVS 08.0009
www.malux.se
= 48 VDC
n