Technibel DSAVM93R5TA Series Installation Manual page 14

Split system air conditioner
Table of Contents

Advertisement

Available languages

Available languages

(1) Basic wiring diagram for group control
This diagram shows when several units (max. 8) are
controlled by a wired controller. In this case, a
wired controller can be connected at any indoor unit.
EG
RED
WHT
BLK
Wired controller
(option)
NOTE
G R.C. Addresses should be set before turning the power on.
G Auto. address setting can be executed by the wired controller automatically.
Please refer to section 7 "PCB Setting".
G Each successive unit will respond at one-second intervals following the order of the R.C. (S2) address when the remote
controller is operating.
Indoor Unit
Inter-unit
power wiring
(Line voltage)
Inter-unit
control wiring
(Low voltage)
E
Indoor Unit
Inter-unit
power wiring
(Line voltage)
Inter-unit
control wiring
(Low voltage)
E
Indoor Unit
Inter-unit
power wiring
(Line voltage)
Inter-unit
control wiring
(Low voltage)
Outdoor Unit
Ground
Ground
Outdoor Unit
Ground
Ground
Outdoor Unit
Ground
Ground
13
*1
R.C. Address on the PCB:
PCB: 1 (S2, BLK)
Power supply
~
380 - 415 V - 3 N
50 Hz
R.C. Address on the PCB:
PCB: 2 (S2, BLK)
Power supply
~
380 - 415 V - 3 N
50 Hz
R.C. Address on the PCB:
PCB: 8 (S2, BLK)
Power supply
~
380 - 415 V - 3 N
50 Hz