TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: DSAF97R5IAA DSAF127R5IAA DSAF187R5IAA DSAF247R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. DSAF97R5IAA 38.7106.008 DSAF127R5IAA 38.7106.009 DSAF187R5IAA 38.7106.010 DSAF247R5IAA 38.7106.011 0.8180.534.0 03/2007...
Page 2
IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating This air conditioning system meets strict safety and operating at connection points and a possible fire hazard.
Table of Contents Page 1. SPECIFICATIONS 1-1 Unit specifications 4-5-6 1-2 Major Component specifications 7-8-9 1-3 Other Component specifications 1-4 Indoor Fan Performance 2. DIMENSIONAL DATA 3. ELECTRICAL DATA 3-1 Electric Wiring Diagrams 4. FUNCTION 4-1 Operation Functions 15-16 4-2 Protective Functions 17-18 4-3 Drain Pump and Float Switch 5.
1. SPECIFICATIONS 1-1 Unit Specifications DSAF97R5I - DSAF127R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 620/560/470 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features...
Page 5
DSAF187R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 865/645/455 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features Microprocessor/ I.C.
Page 6
DSAF247R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 985/760/530 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features Microprocessor/ I.C.
1-2 Major Component Specifications DSAF97R5I - DSAF127R5I Controller PCB Part No. CB-URV93EH DSAF97R5I CB-URV123EH DSAF127R5I Microprocessor Controls 250 V - 3,15 A Control circuit fuse RCS-4HVPN4EX Remote Control Unit Fan & Fan Motor Type Centrifugal fan 2…. Ø 160 / L 240 Q'ty …….
Page 8
DSAF187R5I Controller PCB Part No. CB-URV184EH Microprocessor Controls Control circuit fuse 250 V - 3,15 A RCS-4MHVPNW4EX Remote Control Unit Fan & Fan Motor Centrifugal fan Type 2…. Ø 160 / L 240 Q'ty ……. Dia. and lenght Fan motor model…Q'ty K35417 M02045 …1 4…...
Page 9
DSAF247R5I Controller PCB Part No. CB-URV244EH Microprocessor Controls Control circuit fuse 250 V - 3,15 A RCS-4MHVPNW4EX Remote Control Unit Fan & Fan Motor Centrifugal fan Type 2…. Ø 160 / L 240 Q'ty ……. Dia. and lenght Fan motor model…Q'ty K35417 M02045 …1 4…...
1-4 Indoor Fan Performance If external static pressure is too great (due to long extension of ducts, for example), the air flow volume may drop too low at each air outlet. This problem may be solved by increasing the fan speed using the following procedure: (1) Remove the screw on the electrical component box Booster cable...
6. TROUBLESHOOTING 6-1 Precaution before Performing Inspection or Repair 6-2 Method of Self-Diagnostics ON/OFF button 1HR. TIMER button (reset) button...
Page 22
(1) Self-diagnostics lamps TIMER lamp OPERATION lamp SERVICE lamp + Since the indications cover various units, the corresponding parts listed below may not be present in some models. (2) If the self-diagnostics function fails to operate...