Technibel DSAF97R5IAA Technical Data & Service Manual

Technibel DSAF97R5IAA Technical Data & Service Manual

Split system air conditioner

Advertisement

Quick Links

TECHNICAL DATA
& SERVICE MANUAL
INDOOR UNIT: DSAF97R5IAA
SPLIT SYSTEM AIR CONDITIONER
DSAF127R5IAA
DSAF187R5IAA
DSAF247R5IAA
Model No.
DSAF97R5IAA
DSAF127R5IAA
DSAF187R5IAA
DSAF247R5IAA
0.8180.534.0
03/2007
Product Code No.
38.7106.008
38.7106.009
38.7106.010
38.7106.011

Advertisement

Table of Contents
loading

Summary of Contents for Technibel DSAF97R5IAA

  • Page 1 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: DSAF97R5IAA DSAF127R5IAA DSAF187R5IAA DSAF247R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. DSAF97R5IAA 38.7106.008 DSAF127R5IAA 38.7106.009 DSAF187R5IAA 38.7106.010 DSAF247R5IAA 38.7106.011 0.8180.534.0 03/2007...
  • Page 2 IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating This air conditioning system meets strict safety and operating at connection points and a possible fire hazard.
  • Page 3: Table Of Contents

    Table of Contents Page 1. SPECIFICATIONS 1-1 Unit specifications 4-5-6 1-2 Major Component specifications 7-8-9 1-3 Other Component specifications 1-4 Indoor Fan Performance 2. DIMENSIONAL DATA 3. ELECTRICAL DATA 3-1 Electric Wiring Diagrams 4. FUNCTION 4-1 Operation Functions 15-16 4-2 Protective Functions 17-18 4-3 Drain Pump and Float Switch 5.
  • Page 4: Specifications

    1. SPECIFICATIONS 1-1 Unit Specifications DSAF97R5I - DSAF127R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 620/560/470 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features...
  • Page 5 DSAF187R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 865/645/455 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features Microprocessor/ I.C.
  • Page 6 DSAF247R5I 220 - 240 V ~ 50 Hz Power source 230 V Voltage rating Performance See catalogue with the requested matching Capacity 985/760/530 Air circulation (High/Med./Low) m³/h 49(5) at shipment - 69 (7) with booster cable External static pressure (High) Pa (mm W.G.) Features Microprocessor/ I.C.
  • Page 7: Major Component Specifications

    1-2 Major Component Specifications DSAF97R5I - DSAF127R5I Controller PCB Part No. CB-URV93EH DSAF97R5I CB-URV123EH DSAF127R5I Microprocessor Controls 250 V - 3,15 A Control circuit fuse RCS-4HVPN4EX Remote Control Unit Fan & Fan Motor Type Centrifugal fan 2…. Ø 160 / L 240 Q'ty …….
  • Page 8 DSAF187R5I Controller PCB Part No. CB-URV184EH Microprocessor Controls Control circuit fuse 250 V - 3,15 A RCS-4MHVPNW4EX Remote Control Unit Fan & Fan Motor Centrifugal fan Type 2…. Ø 160 / L 240 Q'ty ……. Dia. and lenght Fan motor model…Q'ty K35417 M02045 …1 4…...
  • Page 9 DSAF247R5I Controller PCB Part No. CB-URV244EH Microprocessor Controls Control circuit fuse 250 V - 3,15 A RCS-4MHVPNW4EX Remote Control Unit Fan & Fan Motor Centrifugal fan Type 2…. Ø 160 / L 240 Q'ty ……. Dia. and lenght Fan motor model…Q'ty K35417 M02045 …1 4…...
  • Page 10: Other Component Specifications

    1-3 Other Component Specifications DSAF97R5I DSAF127R5I DSAF187R5I DSAF247R5I Trasformer (TR) ATR-I55 Rating Primary AC 230 V, 50/60 Hz Secondary 13.7 V - 0.4 A Capacity 5.48 VA Ω (at 25°C) Coil resistance Primary (WHT-WHT): 307 ± 10% Secondary (BRN-BRN): 1.8 ± 10% 150°C Thermal cut-off temp.
  • Page 11: Indoor Fan Performance

    1-4 Indoor Fan Performance If external static pressure is too great (due to long extension of ducts, for example), the air flow volume may drop too low at each air outlet. This problem may be solved by increasing the fan speed using the following procedure: (1) Remove the screw on the electrical component box Booster cable...
  • Page 12: Dimensional Data

    2. DIMENSIONAL DATA DSAF97R5I Unit: mm DSAF127R5I O.D. 9,52mm (3/8)
  • Page 13 DSAF187R5I Unit: mm DSAF247R5I O.D. 12,7mm (1/2) - 18000 Btu O.D. 15,88mm (5/8) - 24000 Btu...
  • Page 14: Electrical Data

    3. ELECTRICAL DATA 3-1 Electric Wiring Diagrams DSAF97R5I DSAF127R5I DSAF187R5I DSAF247R5I...
  • Page 15: Function

    4. FUNCTIONS 4-1 Operation Functions...
  • Page 17: Protective Functions

    4-2 Protective Functions...
  • Page 19: Drain Pump And Float Switch

    4-3. Drain Pump and Float Switch...
  • Page 20: Test Run

    5. TEST RUN 5-1 How to Test Run the Air Conditioner display area HIGH POWER button ON/OFF 1HR. TIMER operation button button...
  • Page 21: Troubleshooting

    6. TROUBLESHOOTING 6-1 Precaution before Performing Inspection or Repair 6-2 Method of Self-Diagnostics ON/OFF button 1HR. TIMER button (reset) button...
  • Page 22 (1) Self-diagnostics lamps TIMER lamp OPERATION lamp SERVICE lamp + Since the indications cover various units, the corresponding parts listed below may not be present in some models. (2) If the self-diagnostics function fails to operate...
  • Page 23: Checking The Indoor And Outdoor Units

    6-3 Checking the Indoor and Outdoor Units...
  • Page 24: Noise Malfunction And Electromagnetic Interference

    6-4 Noise Malfunction and Electromagnetic Interference...
  • Page 25: Checking Electrical Components

    7. CHECKING ELECTRICAL COMPONENTS 7-1 Measurement of insulation Resistance...
  • Page 26: Checking Continuity Of Fuse On Pcb Assy

    7-2 Checking Continuity of fuse on PCB Assy 7-3 Checking Motor Capacitor...
  • Page 27 R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728...

This manual is also suitable for:

Dsaf127r5iaaDsaf187r5iaaDsaf247r5iaa