Download Print this page

Operation - Profi-pumpe DPY01114-4 Operating Instructions

Diesel barrel pumps

Advertisement

2 English
CONTENTS
1.
Introduction ......................................................................................................................................................... 2
2.
In general ........................................................................................................................................................... 2
3.
Ranges of application ......................................................................................................................................... 2
4.

Operation ............................................................................................................................................................ 2

5.
Security tips ......................................................................................................................................................... 3
6.
Servicing ............................................................................................................................................................. 3
7.
Guarantee regulations ........................................................................................................................................ 4
8.
Recognising and repairing of mistakes .............................................................................................................. 4
9.
Notes on Product Liability ................................................................................................................................... 4
10.
Notes on Disposal .............................................................................................................................................. 4
11.
EU Declaration of Conformity ............................................................................................................................. 4
12.
Technical Data .................................................................................................................................................... 8
SAFETy INSTRUCTION AND WARNINGS
Please read the user manual before using
the pump
Warning sign
Warning of electrical voltage
1. INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That's why functional
security and operational safety stands on first place for us.
To prevent damage to persons or property, you should read this user manual carefully. Please
observe all safety precautions and instructions for proper use of the pump. Failure to follow the
instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any
time you can restore them.
2. IN GENERAL
The barrel pumps are developed according to the newest stand of technology, manufactured with much care and go
under strict intensive controls – each pump is checked individually – rests of the check-fluid could be still inside the
pump or on the package. The counter (if available) shows more than 0,0 Liter because of that (usually 5-12L).
The pumps were optimized by us in particular for their special demands.
Make sure after unpacking the pump that the data given on the type label agree with the operating conditions. In the
case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distrib
utor and to us in witten form. By transport with DHL please contact your local DHL office within 7 days.
3. RANGES OF APPLICATION
These pumps are made for pumping diesel or fuel oil ONLY!
They are not suitable for pumping ignitable liquids like gasoline, kerosene, or for pumping at places where the danger
of an explosion exists. When using the pump, make sure there are no open flames, lighters, matches, cigarettes or
similar things present around you. When operating suitable protective gloves must be worn.
These pumps are made for pumping clean diesel / biodiesel or fuel oil ONLY! The pumped liquid should not contain
abrasive components. Abrasive components reduces pump life.
4. OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Also, it
is NOT recommended to perform, for example, a cable extension. It is not certain whether this modification
is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during
prolonged operation.
Diesel pumps are electrical products, which have to be protected against outer influences, f.e. caused by weather.
Only use the pump in well-ventilated rooms and areas with enough fresh air. The floor, on which the pump may be
used, should be flat. Please keep enough space from walls.
The specified suction lift is the maximum suction at optimal conditions. Do not reduce the cross area of suction and
discharge lines.
CAUTION: Do not connect more than 4m of 1" hose on the pressure side. For smaller hose diameters, use
shorter hose. Operation with dispensing guns is not recommended and is therefore at your own risk. These
measures must be strictly adhered to in order to avoid damage to the pump.
Pull power plug
Protective gloves
Protect from rain and moisture
ImPORTANT!
Installation of the barrel pump
1. Connect all parts correctly and ensure outlet connections are in proper placement.
2. Apply power cord to the motor by plugging the power cord into a power source. Turn on the pump by use the on/off swich.
The flow of the 230 volt pump can be adjusted with the flow regulating screw.
3. Refuel as usual.
4. When fueling is complete, return the nozzle to its storage position and turn off the pump.
DIESEL 230V BARREL PUmP
l Do not leave the motor running, when not in operation.
l Clean the fuel strainer regularly.
5. SECURITy TIPS
l Obey absolutely valid regulations on the electrical security
l When operating suitable protective gloves must be worn.
l Never run pump dry
l Never run pump against pressure
l Pumping inflammable, as well as all other aggressive liquids, except of diesel or fuel oil, is prohibited
l Never pump liquid food products
l Before usage, check on the tightness of the hose clamps
l Pay attention to the max. liquid temperature of 35°C
l Never pull the pump on the electrical cable or pressure hose
l Disconnect the plug immediately from the power grid when the line has been damaged or severed
l Switch off pump immediately after usage
l Don't move the pump in any way, while it's running
l During longer unused times, clean the pump, wash it out with diesel or fuel oil, dry and store it at room
temperature
l ALWAYS supervise and watch the pump, while using
l The electrical connections are always to be carried out by an authorised professional
l Operation can not be performed by children and young people under 16 and people with intellectual disabilities
l The pump must be protected from rain and moisture. The pump may only be operated in dry rooms. The
ingress of water into the energized components of the pump increases the risk of electric shock
ThE mANUFACTURER ExPLAINS:
l To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the
instructions in this user manual.
l To reject every responsibility for the damages which originate from the improper use of the pump
6. SERVICING
Under normal pumping conditions the pump requires no servicing.
But it is important to keep the suctions and delivery sections perfectly clean and free from all clogging.
The following controls should be carried out regularly:
l Intactness of the electric cable
l That the connection hoses are not bent or broken
l Cleanness of the pump medium
Moreover, the pump should be emptied at risk of frost, be washed out with diesel/fuel oil and stored dry.
English 3
DIESEL 12V / 24V BARREL PUmP
ATTENTION!
+
--

Advertisement

loading

This manual is also suitable for:

Dpy01116-4Dpy01115-4