2. DISASSEMBLY & REASSEMBLY

2-1. INSTRUMENT DISASSEMBLY

2-l-l. Bottom Cover Removal
1. Remove two (2) screws holding the bottom cover.
2. Release two (2) tabs from the bottom cover.
Fig. 1 Bottom Cover Removal
2-l-2.Top Cabinet Removal
1. Remove three(3)screws located at the rear of the top
cabinet.
2. Carefully lift the back of the top cabinet and slide it to
the rear to remove.
Fig. 2 Top Cover Removal
LEASE TWO TABS
2-l-3. Front Panel Removal
1. Remove bottom cover and top cabinet (See Fig. 1 to
2. Release three (3) tabs from the bottom of the front
panel.
3. Release four (4) tabs from the top of the front panel.
4. Tilt the front panel forward to remove.
THREE TABS
Fig. 3 Front Panel Removal
2-1
EASE FOUR TABS
2).