CONNECTING THE FEEDER CABLE
WARNING: If the power supply cable is
damaged, it must be replaced only by
an authorised service agent in order to
avoid a hazard.
To connect the feeder cable to the cooker
it is necessary to:
Remove the two screws that hold
shield "A" behind the cooker.
Open completely the cable clamp "D".
Position the U bolts onto terminal
block "B" (fig. 10.1) according to the
diagram in figs. 10.2, 10.3.
Insert the feeder cable into the cable
clamp "D". The supply cable must
be of a suitable size (see the section
"Feeder cable section").
Connect the phase and earth cables
to terminal "B" according figures 10.2,
10.3.
Pull the feeder cable and block it with
the cable clamp "D".
Re-mount shield "A".
N.B. The earth conductor must be left
about 3 cm longer than the others.
D
Fig. 10.1
POWER SUPPLY
230 V ac
FEEDER CABLE SECTION
"TYPE H05RR-F"
230 V ac
400 V 3N ac
400 V 2N ac
(**) Connection with wall box connection.
B
A
11100 W
3 x 6 mm
5 x 2,5 mm
4 x 6 mm
Diversity factor applied.
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
2
(**)
2
(**)
2
(**)