2.
Unit Description
2.1 Technical Data of the 400V Class
Voltage class
Rated voltage
Permissible range
Mains frequency
Overload capacity
EN 60146-1-1/
Rating class III
Efficiency @ *
THDI @ *
cos phi *
*
= Rated operation
**
=
At rated voltage > = 460V multiply the rated current with factor 0,86
***
= Upto connection power >= 30kW motor rating power power at frequency inverter
2.2 Ambient Conditions
Storage temperature
Operating temperature
Model / protective system (EN 605
Environment (IEC 664-1)
Climatic categorie (EN 60721-3-3)
2.3 Input Rated Current
Part No.
Irating [A]
10
12.Z1.C04-1000
12,6
13.Z1.C04-1000
17,3
14.Z1.C04-1000
25,2
15.Z1.C04-1000
34,7
16.Z1.C04-1000
44,1
17.Z1.C04-1000
52,5
18.Z1.C04-1000
63
19.Z1.C04-1000
79
20.Z1.C04-1000
95
21.Z1.C04-1000
121
22.Z1.C04-1000
158
23.Z1.C04-1000
189
24.Z1.C04-1000
221
25.Z1.C04-1000
263
26.Z1.C04-1000
315
27.Z1.C04-1000
390
28.Z1.C04-1000
460
29.Z1.C04-1000
400V
400V
360V to 440V
50Hz/ 60Hz **
150% for 60 sec.
All 10 min.
> 99%***
<= 8%
aprox. 0,99
-25...70 °C (-13...158 °F)
-10...45 °C (14...113 °F)
IP20
Pollution degree 2
Weight [kg]
Prating [kW]
12,3
4
13,3
5,5
17,6
7,5
25,3
11
36,3
15
46,3
18,5
55,5
22
63,2
30
73,6
37
92,4
45
107,7
55
159,7
75
171,5
90
214,5
110
237,1
132
272,1
160
340
200
471,9
250
3K3
Terminal [mm
4
4
4
16
16
16
35
35
35
50
50
95
95
95
150
150
2*150
2*240
2
]
PE-connection
M6
M6
M6
M6
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M10
M12
M12
GB - 7
Need help?
Do you have a question about the COMBILINE and is the answer not in the manual?