KEB COMBILINE E6 Instructions For Use Manual
KEB COMBILINE E6 Instructions For Use Manual

KEB COMBILINE E6 Instructions For Use Manual

Hf filter back mount for f6 housing 7
Hide thumbs Also See for COMBILINE E6:
Table of Contents

Advertisement

Quick Links

Instrctions for use
COMBILINE E6
Installation HF Filter Back mount for F6 Housing 7
Translation of the original manual
Document 20344395 EN 00

Advertisement

Table of Contents
loading

Summary of Contents for KEB COMBILINE E6

  • Page 1 Instrctions for use COMBILINE E6 Installation HF Filter Back mount for F6 Housing 7 Translation of the original manual Document 20344395 EN 00...
  • Page 2 Imprint KEB Automation KG Suedstraße 38, D-32683 Barntrup Germany Tel: +49 5263 401-0 • Fax: +49 5263 401-116 E-Mail: info@keb.de • URL: https://www.keb-automation.com ma_dr_e6-hf-filter-geh7-20344395_en Version 00 • Edition 17/01/2024...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Introduction ..............................Markings..............................1.1.1 Warnings..........................1.1.2 Information notes ........................1.1.3 Symbols and markers ......................Laws and guidelines..........................Warranty and liability..........................Support..............................Copyright............................... Validity of this manual ........................... Target group............................General Safety Instructions.......................... Installation ............................. Electrical installation..........................
  • Page 4 Table of Contents KEB Automation KG Connection instructions......................... Mains connection ..........................Connection description.......................... 6.3.1 Ring crimp connector ......................6.3.2 Earth connection screw ......................Maintenance, service and disposal ......................Maintenance............................Service ..............................Disposal ..............................Certification ..............................EU Declaration of Conformity E4, E5, E6 .....................
  • Page 5 List of Figures List of Figures Fig. 1 Schematic diagram HF mains filter for IT, TN and TT systems ............. Fig. 2 Insertion loss 27E6T60-1150 ......................... Fig. 3 Permitted mounting orientation ......................Fig. 4 Mounting distances ..........................Fig. 5 Installation distance between HF filter and mains choke ............... Fig.
  • Page 6 List of Tables KEB Automation KG List of Tables Tab. 1 Technical data............................Tab. 2 NHF combinations..........................Tab. 3 Fuse protection according to IEC......................Tab. 4 Absicherung nach UL Class J ........................ Tab. 5 Fuse protection according to UL type gR / aR ..................
  • Page 7: Introduction | 1

    Introduction | 1 1 Introduction The described devices, accessories, hardware and/or software are products of KEB Automation KG. The enclosed documents correspond to conditions valid at printing. Misprint, mistakes and technical changes reserved. 1.1 Markings 1.1.1 Warnings Certain operations can cause hazards during the installation, operation or there- after.
  • Page 8: Symbols And Markers

    This also applies to any violation of industrial property rights of a third- party. Selection of KEB units in view of their suitability for the intended use must be done by the user. Tests can only be carried out within the scope of the intended end use of the product (Application) by the Customer.
  • Page 9: Copyright

    Copyrights are with KEB Automation KG and re- main valid in its entirety. Other wordmarks and/or logos are trademarks (™) or registered trademarks (®) of their respective owners.
  • Page 10: General Safety Instructions

    2 | General Safety Instructions KEB Automation KG 2 General Safety Instructions The products are developed and built according to the state of the art and recog- nized safety rules. Nevertheless, their use may create dangers to life and limb of the user or third parties or damage to the machine and other material property.
  • Page 11: Start-Up And Operation

    General Safety Instructions | 2 2.3 Start-up and operation High temperatures at the unit! CAUTION Burning of the skin a) Cover hot surfaces safe-to-touch. b) If necessary, attach warning signs on the system. c) Before any working let the unit cool down. d) Check the temperature before touching any parts.
  • Page 12: Product Description

    3 | Product description KEB Automation KG 3 Product description The EMC filters of the product series COMBILINE serve to comply with normative limit values of high-frequency, conducted interference voltages at the mains input of the drive controllers. The filters consist of an LC network that has a particularly high attenuation in the entire frequency range.
  • Page 13: Functional Description

    Product description | 3 10. digit Mains form TN, TT IT, TN, TT 11. digit Version Sequential numbering 3.4 Functional description 3.4.1 IT mains filter 3.4.1.1 Schematic diagram HF mains filter for IT, TN and TT systems ② ① ③ ③ ④ Fig. 1: Schematic diagram HF mains filter for IT, TN and TT systems ①...
  • Page 14: Technical Data

    4 | Technical data KEB Automation KG 4 Technical data 4.1 Operating conditions 4.1.1 Climatic ambient conditions Storage Standard Class Notes Ambient temperature EN 60721-3-1 -25…55 °C Relative humidity EN 60721-3-1 5…95 % (without condensation) Storage height Max. 3000 m above Transportation Standard Class...
  • Page 15: Electrical Operating Conditions

    150 % Power dissipation 50 W Construction and protection class IP00 Suitable KEB housing size F6 / 7 Tab. 1: Technical data 4.2.1 NHF combinations NOTICE! If smaller chokes are used due to the design, the choke must be designed for the current.
  • Page 16: Fuse Protection According To Ul Class J

    4 | Technical data KEB Automation KG 4.2.3 Fuse protection according to UL Class J The following table shows the maximum fuse size of type Class J with a 1:1 dimension and an input voltage of 480 V. In case of other dimension, the val-...
  • Page 17: Fig. 2 Insertion Loss 27E6T60-1150

    Technical data | 4 0.01 f / MHz Fig. 2: Insertion loss 27E6T60-1150 a Asymmetrical insertion loss (common mode) b Unsymmetrical insertion loss (differential mode) c Symmetrical insertion loss (0.1Ω/100Ω system) ma_dr_e6-hf-filter-geh7-20344395_en...
  • Page 18: Assembly

    5 | Assembly KEB Automation KG 5 Assembly 5.1 Assembly instructions Holding lugs designed for own weight only! WARNING ü Too much weight can cause the lugs to tear out a) Only transport filters on their own using the holding lugs. To prevent damage to the product, the following instructions must be observed: •...
  • Page 19: Mounting The Filter/Drive Controller

    Assembly | 5 Electromagnetic compatibility: (► https://www.keb.de/fileadmin/media/Techinfo/dr/ tn/ti_dr_tn-emc-00011_en.pdf) 5.2 Mounting the filter/drive controller • Prepare drill holes • Screw the filter onto the mounting plate. • Tighten the screws to the specified torque. • Connect the filter on the mains side (as it is more accessible).
  • Page 20: Minimum Installation Distances Filter With Drive Controller

    5 | Assembly KEB Automation KG 5.4 Minimum installation distances filter with drive controller Fig. 4: Mounting distances Dimension Distance 150 mm 6 inch 100 mm 4 inch 30 mm 1.2 inch 0 mm 0 inch 0 mm 0 inch 50 mm 2 inch 1) Distance between front of drive unit and control cabinet door.
  • Page 21: Dimensions And Weights

    Assembly | 5 Fig. 5: Installation distance between HF filter and mains choke 5.6 Dimensions and weights Unless otherwise indicated, all length specifications in the following chapter are in ma_dr_e6-hf-filter-geh7-20344395_en...
  • Page 22: Fixing Material

    5 | Assembly KEB Automation KG für M10 (4x) Fig. 6: Dimensions 27E6T60-1150 Material number Weight 27E6T60-1150 28.2 kg 5.7 Fixing material Filters Quantity Fixing material Tightening Suitable for torque 27E6T60-1150 4 pcs Hexagon head screw ISO 4017 M10 - 8.8 50 Nm...
  • Page 23: Electrical Connection | 6

    Electrical connection | 6 6 Electrical connection 6.1 Connection instructions The electrical installation shall be carried out in accordance with the relevant require- ments. With existing or newly wired circuits the person installing the units or machines must en- sure the EN requirements are met. To prevent malfunctions during operation, please pay attention to the following instruc- tions: •...
  • Page 24: Connection Description

    6 | Electrical connection KEB Automation KG 6.3 Connection description L1‘ L2‘ L3‘ Fig. 8: Connection 27E6T60-1150 Filter Function Name Reference 27E6T60-1150 Mains input L1, L2, L3 (≡► 0090809-1038 [} 24]) Drive controller L1‘, L2‘, L3‘ (≡► 0090809-1038 [} 24]) Protective earth (≡► 9927006-130Z [} 24])
  • Page 25: Maintenance, Service And Disposal | 7

    When replacing, only replace with original filter. b) Carefully replace the shielding in particular. Technical support and repairs KEB offers wide-ranging, complete after-sales technical support. The staff who deal with this handle questions on the entire range of products skilfully, quickly, and efficiently.
  • Page 26: Disposal

    14.08.2018. In principle, these devices may not be left at public or communal recycling or collection points. Unless otherwise agreed between the customer and KEB or unless there is a deviating mandatory legal regulation, KEB products labelled in this way can be returned.
  • Page 27: Certification | 8

    Certification | 8 8 Certification see also 2 EU Declaration of Conformity E4, E5, E6 [} 28] 2 UK Declaration of Conformity E4, E5, E6 [} 30] ma_dr_e6-hf-filter-geh7-20344395_en...
  • Page 28 = any number or letter for different versions Voltage category 230 / 400 / 690 V ac This declaration of conformity is issued under the sole responsibility of KEB Automation KG. The above given product is in accordance with the following directives of the European Union Number:...
  • Page 29 Zertifizierungsstelle des RWTÜV Steubenstrasse 53 D - 45138 Essen No. of approval 041 004 500 Dated: 20.10.1994 Valid until: December 2024 KEB Automation KG, Südstr. 38, D-32683 Barntrup www.keb.de E-Mail: info@keb.de Tel.: +49 5263 401-0 Fax: -116 Seite: 2 von 2...
  • Page 30: Declaration Of Conformity

    5 Morris CI, Park Farm Industrial Estate, Wellingborough NN8 6XF, UK Declares under sole responsibility that the product as originally delivered Product Name: KEB Combivert ( Assessories EMC-Filters ) yyE4xxx-xxxx, yyE5xxx-xxxx, yyE6xxx-xxxx Model Number: with yy=05 to 32 and x = 0…9 or A….Z...
  • Page 31: Ul Certification

    Certification | 8 8.3 UL certification An acceptance according to UL is marked on the nameplate by the adjacent logo. To be conform according to UL for use on the North American and Canadian Mar- ket the following additionally instructions must be observed (original text of the UL- File): •...
  • Page 32: Annex

    9 | Annex KEB Automation KG 9 Annex 9.1 Measurement diagrams Interference voltage measurement limit value C2 according to 61800-3. Specifications: Motor cable length 50 m Output frequency 5 Hz Switching frequency 4 kHz ① ② Fig. 9: 27E6T60-1150 Interference voltage measurement C2...
  • Page 33: Revision History | 10

    Revision history | 10 10 Revision history Edition Version Note 2023-05 Series version 2024-01 Voltage specification changed to 480/277V. ma_dr_e6-hf-filter-geh7-20344395_en...
  • Page 34: Glossary

    Glossary KEB Automation KG Glossary Application EN 60721-3-3 The application is the intended use of the KEB Classification of environmental conditions - Part 3: product. Classification of groups of environmental paramet- ers and their severitiesMain section 3: Stationary use at weatherprotected locations (IEC...
  • Page 35 Glossary Residual current circuit breaker; formerly also FI circuit breaker SCCR The Short Circuit Current Rating indicates the maximum short circuit current that the device can withstand. ma_dr_e6-hf-filter-geh7-20344395_en...
  • Page 36: Index

    Index KEB Automation KG Index Insertion loss  16 Limit class  16 Maintenance work  25 Motor cable length  16 Mounting orientation  19 NHF-Kombination  20 Packaging  26 Product features  12 Protective earth  23 Return point  26 Sicherung  15 UL Class J  16 UL Type gR/aR  16...
  • Page 37 MORE KEB PARTNERS WORLDWIDE: www.keb-automation.com/contact...
  • Page 38 Automation with Drive www.keb-automation.com KEB Automation KG • Suedstraße 38 • D-32683 Barntrup • Tel: +49 5263 401-0 • E-Mail: info@keb.de...

This manual is also suitable for:

27e6t60-1150

Table of Contents