All installations and services must be performed by qualified service personnel.
RIELLO BURNER APPLICATION CHART
The optional F3 and F5 Riello flame retention oil burners have been UL listed (UL File #MP3252) for application on
the following Thermo Pride oil fired furnaces.
MODEL
PART
MTG. PLATE
TOP-25752
PART NO.
BTM-35733
MTG. PLATE
GASKET
330090
PART NO.
**NOZZLE
.50-60A
SIZE
NOZZLE
380393
PART NO.
OIL PUMP
170 PSI
PRESSURE
BURNER
BURNER
380215
PART NO.
* A refers to hollow pattern nozzle
** NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is
that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.
For more specific burner information, specifications or service information, reference the training manual enclosed
with each Riello burner or contact:
I. HEAT EXCHANGER CLEANING INSTRUCTIONS:
? ? ? ? WARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED
SERVICE PERSON.
It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot.
A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less
efficiency.
To clean the heat exchanger, first turn off all power to the unit. Next, remove the access panel (see below and
beginning of following page) immediately above the burner (on the horizontal furnace, it will be located to the side
of the burner) to gain entry to the clean-out covers, refer to figure 15. This panel is identified with a label. Remove
clean-out covers, the vent connector pipe to the chimney, the burner, and the burner mounting plates. When
removing the clean-out covers, special care must be taken not to damage the gaskets. Should the gaskets separate,
crack, break, or be unsuitable for reuse, the gasket must be replaced before reattaching the clean-out covers.
OC5, OL5,
OH3
OH5, OT5
35750
330088
.60-60A*
380394
145 PSI
F3
F3
380215
Riello Corporation of America,
Hingham, Massachusetts 02043
OL11, OH11,
OT11
35750
330088
.75-60A*
380395
145PSI
F5
380216
5 Pond Park Road
(617) 749-8292
11
OL16, OH16,
OL20
OT16
35750
35750
330088
330088
.90-60A*
1.10-60A*
380396
380397
145 PSI
150PSI
F5
380216
380216
F5