Table Of Contents ABOUT THIS MANUAL........................1 SAFETY INSTRUCTIONS.......................1 PRODUCT INTRODUCTION ......................2 Features..........................2 Basic System Architecture......................2 Product Overview ........................3 Packing List ..........................3 User Environment ........................4 INSTALLATION ...........................4 Preparation ..........................4 Battery Connection .........................4 PV Connection.........................6 GRID / AC OUTPUT(LOAD) Connection..................7 Three-Phase Unit Connection....................8 Single-Phase Unit Connection....................8 Grounding Connection......................9 Final Assembly........................9...
ABOUT THIS MANUAL APPENDIX: APPROCIMATR BACK-UP TIME TABLE Purpose This manual describes the assembly, installation and troubleshooting of this unit. Please 1082 1674 read this manual carefully before installations and operations. Keep this manual for future 1800 2700 reference. 3600 4500 Scope 5400...
PRODUCT INTRODUCTION 1.Check if communication Fault code 80 CAN data loss cables are connected well This is a multi-function Energy Storage Inverter, combining functions of inverter, On-Grid, Fault code 81 Host data loss and restart the inverter. MPPT solar charger and battery charger to offer uninterruptible power support. It's 2.If the problem remains, Synchronization data loss Fault code 82...
Please refer to typical amperage in below table as required fuse or breaker size. WARNING! All wiring must be performed by a qualified personnel. WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection.
Page 8
Notice: Please only use sealed lead acid battery and Lithium battery. Notice: Please check maximum charging voltage and current when first using this inverter. Grid Notice: Please use 60VDC/300A circuit breaker. 12KW Please follow below steps to implement battery connection: 3*60A Maximum Grid charging current(DC) 3*80A...
WARNING: Shock Hazard 12KW Installation must be performed with care due to high battery voltage in series. 9000W 12000W CAUTION!! Do not place anything between the flat part of the inverter terminal and Output Voltage Regulation 230Vac(L-N)/ 230Vac(P-N) the ring terminal. Otherwise, overheating may occur.
Please follow below steps to implement PV connection: SPECIFICATIONS Step 1: Remove insulation sleeve 8mm and insert conductor into cable ring terminal. Step 2: Check correct connection between the solar panel and the PV input terminal. PV1 12KW terminal is connected with the first group of panel, PV2 terminal is connected with Sinusoidal(utility or generator) the second group of panel, and PV3 terminal is connected with the third group of panel.
Please follow below steps to implement AC connection: WARNING INDICATOR Warning Code Three-Phase Unit Connection Notice: Single-phase and three-phase unit wiring is not the same, cannot be mistaken, otherwise it will cause a short circuit. Notice: Before connecting the grid to this unit, disconnect the PV and battery from the unit,And disconnect the main switch on the grid side.
Single-Phase Unit Three-Phase Unit Connecting To The Ground For safety reasons, the unit must be connected to the earth. The terminal marked "G" on this unit and the hole marked on the box of this unit are connected to earth.
Communication And BTS Connection Stop mode The inverter stop working if you turn off Communication connection the inverter by the soft Please use supplied communication cable to connect to inverter and PC. Insert bundled CD key or error has occurred into a computer and follow on-screen instruction to install the monitoring software.
Operating State Description OPERATION AND DISPLAY PANEL The operation and display panel, shown in below chart, is on the front panel of the inverter. Operation state Description LCD display It includes three indicators, four function keys and a LCD display, indicating the operating sell state PV energy is sold back status and input/output power information.
LCD Display Icons Icon Function description Input Source Information and Output Information Indicates the AC information Indicates the DC information Indicate input voltage, input frequency, PV voltage, battery voltage and charger current. Indicate output voltage, output frequency, load in VA, load in Watt and discharging current.
Display Setting In battery mode, it will present battery capacity. The LCD display information will be switched in turns by pressing "UP" or "DOWN" key. The selectable information is switched as below order: battery voltage, battery current inverter voltage, inverter current, grid voltage, grid current, load in Watt, load in VA, grid frequency, inverter frequency, PV voltage, MPPT charging power, MPPT charging output voltage, MPPT charging current.
Commissioning Step 1: Make sure that the following requirements are met before running this unit. Make sure that the battery and the solar panel are connected correctly to the unit. (See page 4 to 7) Make sure that the GRID and the load are connected correctly to the unit. until user turns keys on.
Page 18
Ifyouunitissingle-phase,itshouldbedisplayasfollow: LCDdisplayinmodules-1of LCDdisplayinmodules-2of LCDdisplayinmodules-3of unit unit unit Notice: in single-phase unit, the modules displays maybe S1, H2, S3 or S1, S2, H3, these condition are normal. Step 4: If there is no more fault alarm, the system is completely installed. Step 5: Please switch on all breakers of Line wires in load side.
LCD Setting After pressing and holding MENU button for 2 seconds, the unit will enter setting mode. Press “UP” or “DOWN” button to select setting programs. And then, press “ENTER” or “MUNE” button to confirm the selection and exit. Setting Programs: can be referred to of the page 29 in this manual.
Need help?
Do you have a question about the PH30 Series and is the answer not in the manual?
Questions and answers