DISASSEMBLY AND ASSEMBLY PROCEDURES

I. Disassembly procedure of main body
[Preparation] Remove the Hot shoe cover FK
1. A401 (Bottom Cover)
① A431・・・Remove the cover by using a coin.
② A61 (Screw, 2mm)
③ A67 x6 (Screw)・・・Do not remove the bottom cover yet.
④ Open the battery cover, and then lift up A401 from rear side as shown in the figure below.
⑤ 0-A412, A419 (Battery cover shaft)
⑥ Unsolder a blue wire, and then remove A401 from the main body.
⑦ A421
⑧ Peel off PT x6.
⑨ A434
⑩ CNL-B1.4x1.6, A424 (Reset switch)
⑪ Unsolder two lands.
2. 0-A301 (Top Cover)
① TY-CNS1.4x2.5・・・Pop-up the built-in flash.
② A70 (Screw (Ni), Inside the battery chamber)
③ A61 (Screw, 2.5mm)
④ A62 (Screw, 3.5mm)
⑤ A63 (Screw, 4.2mm)
⑥ A69 (Screw (TY), 3.5mm)
⑦ A64 x2 (Screw, 11mm)
Eye cap FL and Battery from the main body.
,