Installation

Wall mount
XT
2000
Ozone
Air
There are two fastening clips on the reverse
side of the ozonizer. These may be used
for wall mount. It is recommended that the
ozonizer be mounted above the water level.
This will prevent water from flowing back into
the ozonizer, eg. in the event of a power failure.
Cabinet installation
Tubing loop
Ozone
XT
2000
Air
The ozonizer may be installed in an equipment
cabinet. If the ozonizer is operated in a
small enclosed space such as a cabinet, it is
essential to provide sufficient ventilation to
avoid overheating. If the ozonizer is installed
below the water level, provide a loop of tubing
extending above the water level to avoid water
flowing back into the ozonizer.
Connecting the ozonizer for skimmer
operation with airstones
Connect the air inlet (9) to an air pump using
6/8 mm tubing. Connect the ozone outlet (6)
to the airstone in the skimmer using ozone-
resistant tubing.
If ozone production is turned off while the
ozonizer is still connected to the skimmer, the
air supply must remain on. This will prevent
water from entering the ozone generator.
Connecting the ozonizer for skimmer
operation with an injector
Connect the injector with the ozone outlet (6).
In this setup, airflow through the ozonizer is
provided automatically. To keep the inlet air
free of contaminants (including dust), it is
recommended to use a filter at the air inlet (9).
Setup
1 Mount the ozonizer and power supply in a
dry environment.
2 Connect the tubing for inlet air and ozone.
3 Connect the power suppy: first, insert the
24 volts plug from the power supply into the
socket (7) on the ozonizer, then connect the
power cable with the power supply. Finally,
insert the wall plug on the power cable into
the mains socket.