1.1 Scope of delivery
– Compressor with instruction manual
– Oil dipstick
– Documents accompanying compressed air
vessel
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must not be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must not be sucked in!
1.3 Technical data
see Fig. 1a
1.4 Components
01
Compressor unit
02
Intake filter
03
Oil dipstick
04
Oil drain screw
06
Pressure pipe
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
I/2
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
2
14
Electric motor
2
18
Filter pressure reducer
2
19
Quick-action coupling (clean, regu-
lated compressed air)
2
20
Mist oiler
2
21
Quick-action coupling (oil-mist com-
2
pressed air)
2
25
Bracket
26
Lock (bracket)
1.5 Transport
This tool may also be transported horizon-
tally.
1.6 Commissioning
1.6.1
Before first use
Replace the sealing plug with the oil dip-
stick (item 03) and fill with compressor
oil. For oil quantity, see "Technical data"
chapter.
1.7 Vessel inspections
Compressor with type test: Inspection is
not required prior to commissioning.
Type identification: see compressor type
plate
We recommend that a "qualified person"
perform a pressure test on the vessel, de-
pending on its rate of utilisation, after 10
years in accordance with the Ordinance on
Industrial Safety and Health. Contact any of
our service partners.
It is essential to retain vessel documents
included in the delivery (= certification
documents) for the entire service life of
the vessel. The statutory specified inspec-
tions must be arranged in accordance
with the applicable regulations of the re-
spective country in which the vessel is
used.