Skoda FABIA 2000 Workshop Manual page 49

Hide thumbs Also See for FABIA 2000:
Table of Contents

Advertisement

FABIA 2000
Body Work
Display on V.A.G. 1552
00928
Implausible signal
Locking unit for
CL driver's side
-F220-
wrong equipment
00929
Implausible signal
Locking unit for
CL front pas-
senger's side
-F221-
wrong equipment
00930
Implausible signal
Locking unit for
RL CL -F222-
wrong equipment
00931
Implausible signal
Locking unit for
CL rr -F223-
wrong equipment
Edition 01.05
S00.5319.15.20
Possible cause of fault
Locking unit defective
Cables or plug connections de-
fective
No supply voltage for CL on driv-
er's door
Resistance in the mechanism of
the locking unit and control ele-
ments
other locking unit type fitted
Locking unit defective
Cables or plug connections de-
fective
No supply voltage for CL on pas-
senger's door
Resistance in the mechanism of
the locking unit and control ele-
ments
other locking unit type fitted
Locking unit defective
Cables or plug connections de-
fective
No supply voltage for CL on rear
left door
Resistance in the mechanism of
the locking unit and control ele-
ments
other locking unit type fitted
Locking unit defective
Cables or plug connections de-
fective
No supply voltage for CL on rear
right door
Resistance in the mechanism of
the locking unit and control ele-
ments
other locking unit type fitted
Self-diagnosis for convenience system with LIN databus cable
Rectifying fault
Reading measured value block
⇒ 01-3 page 10
Replace locking unit
Check wiring and plug connec-
tions according to the current flow
diagram
Check supply voltage
Check mechanism and ensure
smooth operation
1)
Replace locking unit
Reading measured value block
⇒ 01-3 page 10
Replace locking unit
Check wiring and plug connec-
tions according to the current flow
diagram
Check supply voltage
Check mechanism and ensure
smooth operation
1)
Replace locking unit
Reading measured value block
⇒ 01-3 page 10
Replace locking unit
Check wiring and plug connec-
tions according to the current flow
diagram
Check supply voltage
Check mechanism and ensure
smooth operation
1)
Replace locking unit
Reading measured value block
⇒ 01-3 page 10
Replace locking unit
Check wiring and plug connec-
tions according to the current flow
diagram
Check supply voltage
Check mechanism and ensure
smooth operation
1)
Replace locking unit
01
01-3
3
page

Advertisement