Magellan MG6250 Section Programming Manual page 29

All-in-one wireless security system
Hide thumbs Also See for MG6250:
Table of Contents

Advertisement

MG6250 • Section Programming Guide
Table 12: Reportable Events/Saved Events (continued)
Event
Event Description
52
Special alarm
53
Paramedic alarm
54
55
New trouble
56
Trouble restore
57
Tamper trouble zone
58
Tamper restore zone
59
Low battery on zone
60
Low battery on zone restore
61
Zone supervision trouble
62
Zone supervision restore
Version 1.0
Sub-event
Special
Sub-event Description
00
Panic emergency
01
Panic medical
02
03
Recent closing
04
Global shutdown
05
Duress alarm
01 - 16
User number
99
Any user number
00
System power up
01
Reporting test
02
Software log on
03
Software log out
04
Installer in programming mode
05
Installer exited programming mode
06
Closing delinquency delay elapsed
00
Telephone line trouble
01
AC failure
02
Battery failure
03
Timer loss trouble
04
Console tamper
05
RF jamming
06
GSM no service
07
GSM supervision loss
08
IP no service
09
IP supervision loss
10
Fail to communicate to central
11
Fail to communicate personal reporting
00
Telephone line trouble restore
01
AC failure restore
02
Battery failure restore
03
Timer loss trouble restore
04
Console tamper restore
05
RF jamming restore
06
GSM no service restore
07
GSM supervision loss restore
08
IP no service restore
09
IP supervision loss restore
10
Fail to communicate to central restore
Fail to communicate personal
11
reporting restore
01 - 64
Zone number
99
Any zone number
01 - 64
Zone number
99
Any zone number
01 - 64
Zone number
99
Any zone number
01 - 64
Zone number
99
Any zone number
01 - 64
Zone number
99
Any zone number
01 - 64
Zone number
99
Any zone number
Panic fire
Description of MG6250 Events | 29
Area
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3,

Advertisement

Table of Contents
loading

Table of Contents