MG6250 • Section Programming Guide
Data Entry
There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select
Programming methods.
Single Digit Data Entry Method
After entering programming mode, some sections will require that you enter decimal values from 000 to 255. Other sections will
require that you enter hexadecimal values for 0 to F. The required data will be clearly indicated in this guide. When entering the
final digit in a section, the MG6250 console will automatically save and advance to the next section. See Decimal and Hexadecimal
Programming Table on page 3 for details on the various keys, and their equivalent decimal and hexadecimal values.
Feature Select Programming Method
After entering certain sections, eight options will be displayed where each option from 1 to 8 represents a specific feature. Press the
key corresponding to the desired option and the option number will appear in the LCD screen. This means the option is ON. Press
the key again to remove the digit from the LCD screen (
options to OFF. When the options are set, press the # key to save and advance to the next section.
Decimal and Hexadecimal Programming Table
Certain sections may require the entry of one or more hexadecimal values. Refer to table 1 for a description of the decimal and
hexadecimal values.
Table 1: Decimal and hexadecimal values
Key
Value or Action
2
Hexadecimal values: A/B/C
3
Hexadecimal values: D/E/F
Deletes value entered
OFF
Toggle between uppercase and lowercase characters
STAY
Enter special characters
SLEEP
Installer Quick-keys
Installer quick-keys provide shortcuts for certain system actions. Refer to table 2 for a description of these quick-keys.
To access the installer quick-keys:
1.
Press and hold 0.
2.
Enter your installer code (default is 0000/000000), or maintenance code.
3.
Press the required quick-keys (see table 2).
Table 2: Installer quick-key values
Key
Value or Action
Test Report: Send the "Test report code programmed in section [1701] to the monitoring station.
OFF
Cancel Communication: Cancels all communication with the PC software or with the monitoring station until the next reportable event.
STAY
Answer PC Software: Will force the console to answer an incoming call from the monitoring station that is using the PC software.
SLEEP
Call PC Software: Will dial the PC telephone number programmed in section [1021] in order to initiate communication with a computer
PHONE
using the PC software.
Installer Test Mode: The installer test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones.
ARM
Press the
Output Reset: Will reset all outputs (on-board and wireless outputs) to their normal state. The normal state of on-board output is set via
#
section [2005].
MG6250 Reset Sections
Table 3: MG6250 Reset sections
Section
[9000]
Resets all programmable sections to factory default values
[9001]
Resets master code
[9002]
Remove module scan (clears missing GPRS module/Sim card trouble)
Version 1.0
key again to exit.
ARM
appears), thereby turning the option OFF. Press the
*
key to set all eight
*
Things You Need to Know | 3