The 2WPGM is a two-way wireless PGM, which
also provides one zone input. After assigning
the PGM module to a system, the PGM can be
programmed to activate and deactivate, as
detailed in the system's programming guide.
Location and Mounting
The 2WPGM must be installed within 35 m
(115 ft.) of the control panel. Before you mount
the 2WPGM, perform the signal strength tests
to ensure optimal performance of the unit.
Do not cut, bend, or alter the antenna.
Avoid mounting the PGM module near or
on metal, as this may affect transmission.
Powering the Unit
The unit requires either AC or DC power input.
For wire connections, see Figure 1.
AC: 6 Vac (500 mA) to 16.5 Vac (200 mA)
DC: 5 Vdc (500 mA) to 24 Vdc (200 mA)
The external power supply used with this
module must be of an Approved/Certified type,
acceptable to the authorities where the module
is installed and used.
Enrollment and Testing
Jumper 2 (JP2) is used for enrolling (Learn
mode) and for testing signal strength.
Learn Mode: Remove and re-install JP2.
Signal Strength: Perform a transmission by
temporarily removing and re-installing JP2, or by
opening the zone that is connected to the PGM.
To interpret the RSSI LED, see the LED
Indicators table.
To test the signal strength of the 2WPGM at the
control panel, see the control panel's
programming guide.
Normal Operation: JP2 must be
normal operation.
Zone Setting
ZONE Jumper determines the input setting of
the zone.
ZONE
CLOSED
ZONE
OPEN
Do not use EOL resistors with universal/zone
inputs.
ZONE
LED Indicator
JP2
for
CLOSED
AC/DC
Power
= Normally Closed (N.C.) zone
(default)
= Normally Open (N.O.)
zone
Figure 1
Antenna
Relay
LED Indicator
Door
PGM
Contact
Output