2 – Features of the CD-RW2000—Connections
Audio signals output from the unit are output from
the balanced and unbalanced
jacks, as well as from the
W
,
DIGITAL COAXIAL OUT
OPTICAL OUT
connector
2.4.1

Word sync connections

It may be necessary to synchronize the CD-RW2000
to an external audio word clock when playing back
material. One example when this might be used is
when the digital outputs of the CD-RW2000 are con-
nected to a digital mixing console, which is serving
as the word clock source for the setup.
In this case, the WORD SYNC OUT of the word
clock master (the digital mixing console) should be
connected to the
WORD SYNC IN
RW2000.
To select the external
WORD SYNC IN
CD-RW2000's clock source:
1 With a disc inserted, and the unit in stop mode
(playback stopped), repeatedly press the
9
6
key (
or
) until the display shows
or
.
2 Use the
control
MULTI DIAL
H
keys
to set the function to
The
indicator
WORD
clock source is available, otherwise the display
will alternate the message
(word clock error) with the time display.
If the CD-RW2000 is receiving a word clock sync
signal, and is also acting as the word clock source for
any units which receive digital audio from the CD-
RW2000 (remember that AES/EBU and IEC60958
signals are self-clocking), the
U
should be set to
.
OFF
NOTE
Entering record ready mode (or record mode) with
the word sync enabled will disable the word sync.
The front panel WORD indicator
If the CD-RW2000 is the last unit in the word clock
chain, the
75
terminator switch
ON
.
14
TASCAM CD-RW2000
N Q
ANALOG OUT
DIGITAL AES/EBU OUT
X
jack
and
DIGITAL
Y
simultaneously.
V
of the CD-
signal as the
MENU
where
is either
B
or the
SKIP
.
7
will light if a valid
terminator switch
75
7
will go out.
U
should be set to
NOTE
There should be one, and only one, word clock source in a
digital audio setup. Multiple word clocks in a setup may
result in damage to equipment.
2.4.2

Control connections

The pinouts of this connector
Pin
Function
1
STOP TALLY OUT
2
REC/PLAY TALLY OUT
3
SKIP (forward) IN
4
SKIP (back) IN
5
REC-PAUSE TALLY OUT
6
REC IN
7
Track increment IN
8
GND
9
PLAY TALLY OUT
10
PAUSE TALLY OUT
11
FADER START/STOP
12
STOP IN
13
PLAY IN
14
PAUSE IN
15
a
+5V
a.The maximum current supplied from this terminal is
50 mA.
Tally signals are open collector, with a maximum
current of 50 mA. Input signals are active when low
(ground) for 30 ms.
A fader start/stop control should be wired according
to the following schematic:
STOP
Pin 8 Ground
START
T
are:
CONTROL I/O
Pin 11 FADER
START/STOP