Table of Contents

Advertisement

Available languages

Available languages

1.1

dimensions

ÉCRAN DE
PROTECTION
ENTRÉE
ÉLECTRIQUE
1.2

plaque d'homologation

EMPLACEMENT DE LA PLAQUE D'HOMOLOGATION : LA PLAQUE EST SITUÉE SOUS LE PANNEAU DE
CONTRÔLE ET FIXÉE PAR UNE CHAÎNETTE À L'APPAREIL. NE PAS ENLEVER.
A
A A A
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
A
WARNING:
APPLIANCE, WHICH WILL COME IN CONTACT WITH
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP
6"
FLOOR
0"
SIDES
0"
BACK
1 1/2"
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS
ARE 4 INCHES AND 10 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS
ARE 36 INCHES AND 10 FEET RESPECTIVELY.
Cette illustration est à titre de référence seulement. Consultez la plaque d'homologation pour obtenir l'information
précise.
NOTE: La plaque d'homologation doit rester avec l'appareil à tout instant. Il ne doit pas être enlevé.
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
37 3/4"
959mm
1 1/4"
32mm
ENTRÉE
DU GAZ
CONFORMS TO ANSI Z21.50-2016, CERTIFIED TO CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE
DIRECT VENT GAS APPLIANCE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE
HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR,
PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOR USE ONLY WITH BARRIER W565-0187. FOLLOW THE INSTALLATION
INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
GT8N
(NATURAL GAS)
0-4500FT (0-1370m)
6,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
DO NOT ADD ANY MATERIAL TO THE
RECESSED DEPTH
7"
VENT TOP
2"
VENT SIDES & BOTTOM
1"
information générale
43 3/4"
1111mm
1 1/4"
32mm
30 11/16"
779mm
5 1/2"
140mm
MODEL
GT8P
(PROPANE)
ALTITUDE
0-4500FT (0-1370m)
INPUT
6,000BTU/h
MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
VENTED DECORATIVE GAS APPLIANCE NOT FOR USE WITH SOLID FUEL. FOR
USE WITH GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT
KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY
LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT
PROHIBITED BY LOCAL CODES. SEE OWNER'S MANUAL FOR DETAILS. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A
CERTIFIED KIT IS USED.SYSTEM.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
GT8
SERIAL NUMBER:
14" 356mm
3" 76mm DIA.
7"
5" 127mm DIA.
178mm
6 3/4"
171mm
12"
305mm
WOLF STEEL LTD.
W385-1981 / A
W415-1367 / B / 01.09.19
FR
49