PA-800 Front Panel..........................15 PA-800 Back-Panel...........................18 Install the PA-800 Series Firewall..............19 Install the PA-800 Series Firewall in a Two-Post 19-inch Equipment Rack....... 21 Install the PA-800 Series Firewall in a Four-Post 19-inch Equipment Rack.......22 Connect Power to a PA-800 Series Firewall Overview......25 Connect Power to a PA-800 Series Firewall..................
Read the following topics before you install or service a Palo Alto Networks next-generation ® firewall or appliance. The following topics apply to all Palo Alto Networks firewalls and appliances except where noted. > Tamper Proof Statement > Third-Party Component Support...
Tamper Proof Statement To ensure that products purchased from Palo Alto Networks were not tampered with during shipping, verify the following upon receipt of each product: • The tracking number provided to you electronically when ordering the product matches the tracking number that is physically labeled on the box or crate.
Product Safety Warnings To avoid personal injury or death for yourself and others and to avoid damage to your Palo Alto Networks hardware, be sure you understand and prepare for the following warnings before you install or service the hardware. You will also see warning messages throughout the hardware reference where potential hazards exist.
Page 10
(c.a. ou c.c.) des entrées d’alimentation et mettez le matériel hors tension. The following applies only to Palo Alto Networks firewalls that support a direct current (DC) power source: French Translation: Les instructions suivantes s’appliquent uniquement aux pare-feux de Palo Alto Networks prenant en charge une source d’alimentation en courant continu (c.c.):...
First Supported Software Release: PAN-OS ® The following topics describe the hardware features of the PA-800 Series firewalls. To view or compare performance and capacity information, refer to the Product Selection tool. > PA-800 Front Panel > PA-800 Back-Panel...
PA-800 Front Panel The following image shows the front panel of the PA-800 Series firewall and the table describes each front panel component. The only differences between the PA-820 (shown) and PA-850 front panel is the model name and the Ethernet port speeds as described in the table.
Ground stud Use the single post ground stud to connect the firewall to earth ground (ground cable not included). Cooling fans Fans that provide ventilation and cooling for the firewall. PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | PA-800 Firewall Overview...
Install the PA-800 Series Firewall The PA-800 Series next-generation firewall ships with two rack-mount brackets for installation in a two-post 19” equipment rack. If you install the firewall in a four-post rack, purchase and install the four-post rack kit (PAN-PA-1RU-RACK4) to secure the firewall to the back rack- posts.
Install the PA-800 Series Firewall in a Two- Post 19-inch Equipment Rack The following procedure describes how to install the PA-800 Series firewall in a two-post equipment rack. When installing the firewall in a two-post equipment rack, ensure the rack is properly anchored and it can support the weight of the installed equipment.
Install the PA-800 Series Firewall in a Four- Post 19-inch Equipment Rack The following procedure describes how to install the PA-800 Series firewall in a four-post equipment rack. Before you begin, make sure you purchased the back brackets (PAN-PA-1RU-RACK4) to secure the firewall to the back rack-posts.
Connect Power to a PA-800 Series Firewall Overview PA-800 Series firewalls operate on AC power and requires a 100-240VAC (50-60 Hz) power source. The PA-820 firewall has one power supply and the PA-850 firewall has two power supplies (the second power supply is for redundancy).
Connect the second power cord through a different circuit breaker to provide power redundancy and to allow for electrical circuit maintenance. PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Connect Power to a PA-800 Series Firewall Overview 2019 Palo Alto Networks, Inc.
Page 28
PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Connect Power to a PA-800 Series Firewall Overview...
Service the PA-800 Series Firewall Hardware The following topics describe how to interpret the PA-800 Series firewall status LEDs and how to replace a PA-850 power supply. The PA-820 firewall does not have serviceable components. > Interpret the LEDs on a PA-800 Series Firewall...
Page 32
Off—The system detected a loss of power, either due to loss of power connection, a failed power supply, or incorrect input voltage. If this occurs, the front panel PWR and ALARM LEDs turn red. PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Service the PA-800 Series Firewall Hardware 2019 Palo Alto Networks, Inc.
Connect one end of the AC power cable to the power supply and connect the other end to a grounded AC power source. Secure the power cord to the power supply with the Velcro strap. PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Service the PA-800 Series Firewall Hardware 2019 Palo Alto Networks, Inc.
Page 34
PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Service the PA-800 Series Firewall Hardware...
PA-800 Series Firewall Specifications The following topics describe the PA-800 Series firewall hardware specifications. For feature, capacity, and performance information, refer to the PA-800 Series firewall datasheet. > PA-800 Series Physical Specifications > PA-800 Series Electrical Specifications > PA-800 Series Environmental Specifications...
The following table describes PA-800 Series firewall miscellaneous specifications. Specification Value Storage capacity One 240GB SSD for system files and log storage. Mean time between failures 35 years (MTBF) PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | PA-800 Series Firewall Specifications...
Palo Alto Networks obtains regulatory compliance certifications to comply with the laws and regulations in each country where there are requirements applicable to our products. Our products meet standards for product safety and electromagnetic compatibility when used for their intended purpose. To view compliance statements for the PA-800 Series firewalls, see .
Country of Origin: Made in the USA with parts of domestic and foreign origin. Input Frequency: 50-60 Hertz (Hz) Input Voltage (AC): 100 to 240 Volts PA-800 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | PA-800 Series Firewall Compliance Statements Overview 2019 Palo Alto Networks, Inc.