Maintenance; Technical Characteristics; Troubleshooting - DeLonghi TRNS Series Instructions For Use Manual

Oil filled radiator
Table of Contents

Advertisement

Adjusting the thermostat
When the room has reached the required temperature, slow-
ly turn the thermostat anticlockwise until the indicator light
goes off (or to the position marked by a click) and no further.
The set temperature will then be regulated automatically
and kept constant by the thermostat.
Frost protection function
With the thermostat in position
in ON position («I»), the appliance maintains the room at a
temperature of about 5˚C, preventing freezing with mini-
mum energy consumption.

MAINTENANCE

Before carrying out any operation on the radiator, unplug
from the electric mains and wait for it to cool.
The oil-filled electric radiator requires no particular mainte-
nance.
It is sufficient to remove the dust with a soft, dry cloth. Never
use abrasive powders or solvents. If necessary remove con-
centrations of dirt using a vacuum cleaner.

TECHNICAL CHARACTERISTICS

Supply voltage
Absorbed power

TROUBLESHOOTING

PROBLEM
The appliance doesn't work
and the switch pressed
See rating plate
"
CAUSE
Be sure it is plugged in and that the
electrical outlet is working.
The unit has reached a too high internal
temperature
The temperature may be set too low.
The thermostat may be set too low.
Plug into the power outlet.
Check that the unit is not covered and let the
appliance cool down.
If the appliance doesn't work please contact
the De'Longhi Customer Experience.
Set the temperature to a higher value.
Turn the thermostat clockwise to a higher
setting until the heater restarts.
6
SOLUTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trns0505m

Table of Contents