40 www.electrolux.com
Problem
The appliance does
not heat up.
The appliance does
not heat up.
The lamp does not
operate.
If you cannot find a solution to the prob-
lem yourself, contact your dealer or the
service centre.
We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)

14. INSTALLATION

WARNING!
Refer to the Safety chapters.
The built-in unit must meet the
stability requirements of DIN
68930.
The oven is designed to be connected to
230 - 240V ~ (50Hz) electricity supply.
The oven has an easily accessible termi-
nal block which is marked as follows:
Connection via
Cooker Control
Circuit
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts
and of a type suitable for the required
load in compliance with the current regu-
lations.
The switch must not break the yellow and
green earth cable at any point.
Possible cause
The Child Lock is activated.
The fuse is released.
The lamp is defective.
Min. size Cable/
flex
2,5 mm²
Refer to "Activating and de-
activating the Child Lock
function".
Make sure that the fuse is
the cause of the malfunc-
tion. If the fuse releases
again and again, contact a
qualified electrician.
Replace the lamp.
The necessary data for the service centre
is on the rating plate. The rating plate is
on the front frame of the appliance cavity.
.........................................
.........................................
.........................................
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.
For UK use only
Cable/flex type
PVC / PVC twin
and earth
After installation and connecting,
the cable must be placed so that
it cannot at any point reach a tem-
perature of more than 50°C above
the ambient temperature.
Before the oven is connected,
check that the main fuse and the
domestic installation can support
the load; and that the power sup-
ply is properly earthed.
Remedy
Fuse
min: 15 A
max: 20 A