S Video Out Chroma Level Adjustment; (Vc-283 Board); Video Out Y, Chroma Level Check (Vc-283 Board) - Sony DCR-TRV40 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

3. S VIDEO OUT Chroma Level Adjustment

(VC-283 Board)

Mode
Camera
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75Ω terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Cr level: A = 714 ± 14mV (NTSC)
Specified Value
Cb level:B = 714 ± 14mV (NTSC)
Burst level: C = 286 ± 6mV (NTSC)
Note:
The data of page: 0, address: 10 must be "00".
Switch setting:
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
0C
02
3
C
26
4
C
26
5
C
27
6
C
27
7
8
3
0C
00
9
0
01
00
0.28 µsec (NTSC)
0.23 µsec (PAL)
Fig. 5-3-8.
A = 700 ± 14mV (PAL)
B = 700 ± 14mV (PAL)
C = 300 ± 6mV (PAL)
Procedure
Set the data.
Set the data, and press PAUSE
button.
Change the data and set the Cr
signal level (A) to the specified
value.
Press PAUSE button.
Change the data and set the Cb
signal level (B) to the specified
value.
Press PAUSE button.
Check that the burst signal level
(C) is satisfied the specified value.
Set the data, and press PAUSE
button.
Set the data.
H
A
B
0.28 µsec (NTSC)
0.23 µsec (PAL)
DCR-TRV40/TRV40E/TRV50/TRV50E

4. VIDEO OUT Y, Chroma Level Check (VC-283 Board)

Mode
Subject
Measurement Point
Measuring Instrument
Specified Value
Note: The data of page: 0, address: 10 must be "00".
Switch setting:
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
1
3
0C
2
3
4
3
0C
A
C
5-57
Camera
Arbitrary
Video terminal of AUDIO VIDEO
jack (75Ω terminated)
Oscilloscope
Sync level: A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level: B = 286 ± 18(mV (NTSC)
B = 300 ± 18mV (PAL)
Procedure
02
Set the data, and press PAUSE
button.
Check that the sync signal level
(A) satisfies the specified value.
Check that the burst signal level
(B) satisfies the specified value.
00
Set the data, and press PAUSE
button.
H
Fig. 5-3-9.
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv40eDcr-trv50Dcr-trv50e