4 Rotary hammer
Note
For details of the rated voltage, frequency, current and/or input power, refer to the country-specific
type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Weight in accordance with EPTA procedure 01
Ø Hammer drill bits
Ø Drill bits for wood
Ø Drill bits for metal
4.1 Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance with
a standardized test and may be used to compare one power tool with another. They may be used for a
preliminary assessment of exposure.
The data given represents the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools or is poorly maintained, the data may vary. This may
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: Maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound (power) level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration information
Vibration emission value for chiseling (a
Vibration emission value for hammer drilling in concrete (a
Uncertainty for the given vibration value (K)
5 Operation
Fitting the side handle
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
▶ Remove the depth gauge from the tool.
CAUTION
Risk of injury! Loss of control over the rotary hammer drill.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the
clamping band is engaged in the groove in the tool.
Printed: 10.10.2017 | Doc-Nr: PUB / 5071226 / 000 / 06
)
WA
)
WA
)
pA
)
pA
)
h, Cheq
TE 7­C
3.5 kg
5 mm ...28 mm
3 mm ...20 mm
≤ 13 mm
100 dB(A)
3 dB(A)
89 dB(A)
3 dB(A)
14 m/s²
)
17 m/s²
h, HD
1.5 m/s²