Valve filters
Table of Contents

Advertisement

9
Backwash: Backwash: During the backwash cycle, water enters tank #2 through the center of the distribu-
tion tube and flows up- wards in the tank#2 expanding the media bed and carrying any precipitated contami-
nants trapped within the bed. It then travels to tank #1 through the center of the distribution tube and flow
upwards in tank #1 and then out to the drain.
Brine Draw: During the brine draw cycle, brine water enters tank #2 through the center of the distribution
tube and flows upwards in the tank #2 regenerating the media bed. It then travels to tank #1 through the cen-
ter of the distribution tube and flows upwards in tank #1 and then out to the drain.
Settle Rinse : During the settle rinse cycle, water enters tank #1 down through the bed and up the through
the center of the distribution tube. It then travels to tank #2 down through the bed and up the through the
center of the distribution tube and out to the drain.
Refill : During refill the control valve will put water into the brine tank for the next regeneration cycle.
Backwash
To
Drain
Tank 1
Tank 2
Regeneration Process Explained
Brine Draw
From
Brine
Tank
Tank 1
Tank 2
Settle Rinse/Service
To
Drain
Tank 1
Tank 2
Refile