Z5396 Y Base plate 1.1 Safety 1.1.1 Intended use The Z5396 must only be used for ground stacked applications in connection with d&b Y-Series Y8 and Y12 cabinets as described in this manual. The Base plate is not intended for flown use.
2. Place the first cabinet onto the Base plate until the cabinet's slots fit into the corresponding fixtures on the Base plate. 3. Insert and lock the Locking pins of the Base plate on both sides. d&b Z5396 Rigging manual 1.1 en...
Page 6
ArrayCalc simulation and insert and lock one Locking pin in the appropriate hole. 5. Attach the next cabinet 1. Attach the next cabinet to the Front links. 2. Insert and lock the Locking pins on both sides. d&b Z5396 Rigging manual 1.1 en...
Base plate, the angle is limited to 15° since the front rubber feet should always rest on the top panel of the subwoofer. Þ To perform the alignment, slightly slacken the hand bolt, align the assembly and retighten the hand bolt. d&b Z5396 Rigging manual 1.1 en...
▪ Inspection for missing ball bearings and damage. ▪ Functional inspection of the release mechanism to ensure it operates properly. ▪ Regularly lubricate the Locking pins using WD-40 ® or a similar product. d&b Z5396 Rigging manual 1.1 en...
Declarations 4.1 Manufacturer's declaration This declaration covers: ▪ d&b Z5396 Y Base plate. National standards and technical specifications applied: DIN 18 800, DIN 1055, DGUV Vorschrift 17. Backnang, 2014-08-05 Frank Bothe, Chief Technology Officer (CTO) d&baudiotechnik GmbH 4.2 Disposal When out of use the rigging components must be disposed of in accordance with the national environmental regulations.