MONTAGE INSTRUCTIONS OF 1250 EXTERNAL MOTOR
Montage of Hanging Bar:
There are 2 pieces L formed hanging plates for installation of
external motor to appropriate place. These are given with screw set.
Screw these plates with M5 x 40 thumbscrews to M5 turnscrews on
external motor cabinet. Photo 1
Photo 1
DRIVING WALL PLUGS IN
Drive 8mm holes on the surface that external motor will be hang.
Nail Ø10 mm wall plugs to (A,B) holes. (Photo 2)
Photo 2
NAILING WALL PLUGS
Nail hanging screws to 10mm wall plugs with (A,B) 5,5x60
A
B
thumbscrews. There should be 5mm distance between screw head
and wall. Photo 3
Photo 3
Montage of Plastic Chimney Fix Plastic Chimney to motor
connection plate with 3,5x9,5 screw. Photo 4
Photo 4
Hanging External Motor
Holding external motor on its body, hang it on the wall with (L) plate
A
B
that you connected previously through A and B points. Photo 5
Photo 5
MONTAGE OF ALUMINUM FLEXIBLE DUCTS
Photo 6
Photo 7
Mount the aluminum flexible duct on plastic chimney that is on top of the hood. (Photo 6)
Mount the other end of aluminum flexible duct to air-inlet of external motor. (Photo 7 and
Photo 9). Then mount one end of the aluminum flexible duct to air-outlet of external
motor (Photo 8, Photo 4, Photo 9) and the other end to the chimney that is used to let
Photo 9
Photo 8
air off.In order to prevent aluminum ducts and chimneys to disconnect because of air
circulation, strengthen their connectin using bracket.
Cable of Chimney
Cable of External
Hood
Cable Connection
Necessary connections should be done in order to control external motor using chimney
hood. Connect cable of chimney hood to cable of external motor. (Photo 10-11)
MONTAGE INSTRUCTIONS OF 1240 EXTERNAL MOTOR
Montage of Hanging Bar:
There are 2 pieces L formed hanging plates for installation of
external motor to appropriate place. These are given with screw set.
Screw these plates with M5 x 40 thumbscrews to M5 turnscrews on
external motor cabinet. Photo 1
Photo 1
DRIVING WALL PLUGS IN
Drive 8mm holes on the surface that external motor will be hang.
Nail Ø10 mm wall plugs to (A,B) holes. (Photo 2)
Photo 2
NAILING WALL PLUGS
Nail hanging screws to 10mm wall plugs with (A,B) 5,5x60
thumbscrews. There should be 5mm distance between screw head
and wall. Photo 3
Photo 3
Montage of Ø 200 mm Plastic Chimney Adaptor
Mount Ø 200mm Plastic Chimney Adaptor to air-outlet of external
motor and fix it to the chimney hood with 3,5x9,5 screw. Screws are
given with screw set. Photo 4
Photo 4
Photo 10
Photo 11
Motor