Configuration Screen; Check The Save Log - HANYOUNG NUX GR200 Series User Manual

Touch-type graphic recorder
Table of Contents

Advertisement

Configuration screen

1. Check the save log

It is possible to search up to 4 hours with the period of 1 second of the measurement
of lapsed time on the operating screen.
Read the file to check it in the internal memory or the SD card as the graph.
6
1
Go to the menu screen.
2
Display the file recorded in the SD card. It is activated if the file is not being saved to the
SD card.
3
Transfer the date recorded in the internal memory to the SD card.
It is activated if the file is not being saved to the SD card.
4
Display the file recorded in the internal memory.
It is activated if the file is not being saved to the internal memory.
5
Select the time and the size axes.
6
Display the time for each grid.
7
Display the data location indicated by the benchmark line.
8
It is the benchmark line for the channel display.
9
Go to the first part of the data.
10
Move to the previous page.
11
Move to the previous pixel. Move to every 10 or 20 pixels if long pressed.
12
Move to the next pixel. Move to every 10 or 20 pixels if long pressed.
13
Move to the next page.
14
Go to the end of data.
15
Magnify the time axis. It is impossible to magnify more than the saving period.
16
Reduce the time axis. The reduction ratios are 1, 2, 4, 8 and 16 times.
9
10
11
12
Fig. 26) View the history button - Time axis
5
4
3
2
1
13
14
15
16
7
8
19

Hide quick links: