2.4 Health and Safety Recommendations
All components must be dry before being connected to an external power supply.
3 Technical Data
3.1 Blast proofing
3.2 Model:
Labeling:
II (1) G [Ex op is Ga] IIC T4
II (1) D [Ex op is Da] IIIC T135°C
I (M1) [Ex op is Ma] I
II 3(1)G Ex nA [op is Ga] IIC T4 Gc X bzw.
Special conditions (A marking with "X" is required): If used in areas ehere equipment of
Category 3 is required, the optical transceiver must be installed in an enclosure which has
been tested separately.
Test certification:
3.3 General Data
Dimensions (LxWxH):
Operating temperature:
Storage temperature:
Housing material:
Mass:
3.4 Electrical Data
Power supply:
Power consumption:
Page | 19
P-Ex
P-Ex OTR opis 1000
P-Ex OTR opis MC
-40°C ≤ Ta ≤ +80°C
IBExU 11ATEX1133
For further data, see EC Type Examination Certificate
104 x 29 x 114 mm
-40°C to +80°C, 10 to 90% relative humidity,
non-condensing
-40°C to +80°C, 10 to 90% relative humidity,
non-condensing
Aluminum
325 g
Model P-Ex***DC
≤ 2W
P
max
OTR
bzw.
II (2)G [Ex op is Gb] IIC T4
bzw.
II (2)D [Ex op is Db] IIIC T135°C
bzw.
I (m2) [Ex op is Mb] I
II 3(2)G Ex nA [op is Gb] IIC T4 Gc X
Power supply: DC supply redundant
Nominal voltage: +10V to +30V DC
Recom. fuse: 1 Ampere (slow-blow)
opis
100