Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The premounted filter insert must be used to ensure
a normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect the
function and/or lead to damages to the shower. Hans-
grohe will not be held liable for this type of damage.
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Assembly see page 40
Do not use silicone containing acetic acid!
Dimensions (see page 31)
Flow diagram
(see page 33)
i
Installation example
(see page 32)
Warm water
Cold water
The wall must be reinforced in this
area.
Plug the unused outlet.
Spare parts(see page 46)
Cleaning (see page 44) and en-
closed brochure
Test certificate (see page 48)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 60°C
max. 70°C / 4 min