Errors
E:18 or indicator for water
supply lights up.
1
E:22 lights up.
E:24 lights up.
1
Depending on the appliance specifications
Cause
Water tap is turned off.
Water tap is jammed or
furred up.
Filter in the water supply is
blocked.
Filters are soiled or blocked.
Wastewater hose is blocked
or kinked.
Siphon connection is still
sealed.
Cover of the wastewater
pump is loose.
Troubleshooting en
Troubleshooting
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply
5.
hose
Clean the filter.
6.
Re-insert the filter in the supply
7.
hose.
Screw the water connection back
8.
on.
Check the water connection for
9.
leaks.
Restore the power supply.
10.
Switch the appliance on.
11.
Clean the filters.
→ "Cleaning filters", Page 44
Reposition the wastewater hose
1.
without kinks.
Remove residues.
2.
Check the connection to the siphon
and open if necessary.
Secure the cover of the Wastewater
pump → Page 58 so it clicks into
position.