Resetting runtime / energy usage
Proceed as follows to reset runtime and energy usage.
• The indicator at the top on the right must be set to current consumption and not to the maxi-
mum measured current.
• The indicator at the bottom must show the runtime.
• The indicator top left does not matter.
• The display should look like the following image, although the numeric values may differ.
• Now press and hold the "Set" button for about 3 seconds until you can hear a short beep.
The values for runtime and total energy usage have been erased.
Disposal
a) General
The product must not be disposed in the household waste.
Dispose of the product at the end of its serviceable life in accordance with the current
statutory requirements; e.g., return it to any suitable collection point.
Remove any normal or rechargeable batteries inserted and dispose of them separately from
the product.
b) Disposal of spent rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all spent rechargeable
batteries; disposal of them in the household waste is prohibited!
Contaminated rechargeable batteries are labelled with these symbols to indicate
that disposal in the domestic waste is forbidden.
The symbols of the relevant heavy metals are: Cd = Cadmium, Hg = Mercury, Pb =
Lead.
You can return used rechargeable batteries free of charge to any collection facility
in your local authority, to our stores or to any other store where rechargeable bat-
teries are sold.
You thereby fulfil your statutory obligations and contribute to the protection of the environment.

Technical Data

Parameter
Operating voltage
Power consumption
Max. power/current
Measuring range for voltage (V)
Measuring range for current (A)
Measuring range for effective
power (W)
Measuring range for frequency (Hz)
Measuring range kWh
Measuring range for power factor
Button cell batteries
Dimensions (H x W x D) in mm
Weight
Ambient conditions
Value
Accuracy
(for 23°C (+/- 5°C))
230 V/AC 50 Hz
<1 W
3680 W/16A
190 – 276 V
+/-3%
0.005 – 16.00 A
+/-(3% + 0.01 A)
1 – 3680 W
+/-(3% + 2 W)
45 – 65 Hz
+/-2 Hz
0.00 – 9999.99 kWh
+/-(5% + 0.1 kWh)
0,70 – 1,00
+/- 0.1 (for >1A, sine,
50 – 60 Hz)
2 x LR44
130 x 63 x 80
approx. 160 g
5 - 40 °C/max. 90%rH (not condensing)
Operating altitude: max. 2000 m (above MSL)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
125333_V4_1116_01_VTP_m_en

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents