PR electronics 5132 Manual

2-wire transmitter-repeater
Table of Contents
  • Dansk

    • Table of Contents
    • Advarsler
    • Sikkerhedsregler
    • Overensstemmelseserklæring
    • Adskillelse Af SYSTEM 5000
    • Anvendelse
    • Teknisk Karakteristik
    • Indgang / Transmitterforsyning
    • Udgang / Forsyning
    • Elektriske Specifikationer
    • Bestillingsskema
    • Blokdiagram
    • Applikation
  • Français

    • Application
    • Avertissements
    • Déclaration de Conformité
    • Démontage du SYSTEME 5000
    • Applications
    • Caractéristiques Techniques
    • Entrée / Alimentation du Transmetteur
    • Sortie / Alimentation du PR-5132
    • Spécifications Électriques
    • Référence de Commande
    • Schéma de Principe
  • Deutsch

    • Application
    • Warnung
    • Sicherheitsregeln
    • Konformitätserklärung
    • Zerlegung des Systems 5000
    • Anwendung
    • Ausgang / Versorgung
    • Eingang / Messumformerversorgung
    • Elektrische Daten
    • Technische Merkmale
    • Bestellangaben
    • Blockdiagramm
    • Anwendung

Advertisement

Available languages

Available languages

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
®
signals as well as HART
signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
and
digital
5 1 3 2
2 - W i r e
T r a n s m i t t e r - R e p e a t e r
N o . 5 1 3 2 V 1 0 3 - I N ( 0 8 3 4 )
F r o m s e r . n o . 9 7 0 0 9 6 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5132 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PR electronics 5132

  • Page 1 Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces analogue digital ® signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 &...
  • Page 2: Table Of Contents

    2-TRÅDS TRANSMITTER-REPEATER PRetrans type 5132 INDHOLDSFORTEGNELSE Advarsler ........2 Sikkerhedsregler .
  • Page 3: Sikkerhedsregler

    SIGNATURFORKLARING PR electronics A/S, Lerbakken 10, 8410 Rønde, Danmark tlf: +45 86 37 26 77. Installation og tilslutning af modulet skal følge landets gældende regler for instal- Trekant med udråbstegn: Advarsel / krav. Hændelser der kan lation af elektrisk materiel bl.
  • Page 4: Overensstemmelseserklæring

    I det omfang, instruktionerne i denne manual ikke er nøje overholdt, vil kunden CE-mærket for overensstemmelse med lavspændingsdirektivet blev tilføjet i ikke kunne rette noget krav, som ellers måtte eksistere i henhold til den indgåede året: 1997 salgsaftale, mod PR electronics A/S. Rønde, 19. august 2008 Peter Rasmussen Producentens underskrift...
  • Page 5: Adskillelse Af System 5000

    ADSKILLELSE AF SYSTEM 5000 2-TRÅDS TRANSMITTER-REPEATER 5132 Husk først at demontere tilslutningsklemmerne med farlig spænding. • Repeater for 2-trådstransmitter 4...20 mA Modulet frigøres fra DIN-skinnen ved at løfte i den nederste lås, som vist på • Isoleret indgang / udgang (3,75 kVAC) billede 1.
  • Page 6: Elektriske Specifikationer

    ELEKTRISKE SPECIFIKATIONER: GOST R godkendelse: VNIIM, Cert. No.......... Ross DK.ME48.V01899 Specifikationsområde: Overholdte myndighedskrav: Standard: -20°C til +60°C EMC 2004/108/EF Emission og immunitet ...... EN 61326-1 Fælles specifikationer: LVD 2006/95/EF ......... EN 61010-1 Forsyningsspænding ........10...35 VDC PELV/SELV ..........IEC 364-4-41 og EN 60742 Vdrop standard ...........
  • Page 7: Bestillingsskema

    BESTILLINGSSKEMA: APPLIKATION: Type Version Kanaler 5132 Standard : A 1 kanal 2 kanaler Modtagende udstyr +V forsyning TEST Indgang BLOKDIAGRAM: 2-Tråds CH 1 transmitter Modtagende udstyr Forsyning + +V forsyning KANAL 1 2-tråds TEST Indgang forsyn. test 2-tråds trans- mitter 2-Tråds...
  • Page 8 2-WIRE TRANSMITTER-REPEATER PRetrans type 5132 TABLE OF CONTENTS Warnings ........14 Safety instructions .
  • Page 9: Warnings

    General mounting, connection and disconnection of wires. Troubleshooting the module. Repair of the module and replacement of circuit breakers must be done by PR electronics A/S only. WARNING! SYSTEM 5000 must be mounted on DIN rail according to DIN 46277.
  • Page 10: Safety Instructions

    All modules fall under Installation Category II, Pollution Degree 1, and Insulation To the extent the instructions in this manual are not strictly observed, the Class II. customer cannot advance a demand against PR electronics A/S that would otherwise exist according to the concluded sales agreement. MOUNTING:...
  • Page 11: Declaration Of Conformity

    As manufacturer First, remember to demount the connectors with hazardous voltages. By lifting PR electronics A/S the bottom lock, the module is detached from the DIN rail as shown in picture 1. Then, by lifting the upper lock and pulling the front plate simultaneously the PCB Lerbakken 10 is removed as shown in picture 2.
  • Page 12: Applications

    Response time (0...90% / 100...10%) ..≈ 2 ms Calibration temperature ......20...28°C APPLICATIONS: The PRetrans 5132 transmitter is ideal for galvanic isolation of 4...20 mA current Temperature coefficient ......< ±0.01% of span / °C Linearity error ..........< ±0.1% of span signals from 2-wire transmitters.
  • Page 13: Order

    VNIIM, Cert. No.......... Ross DK.ME48.V01899 Type Version Channels Observed authority requirements: Standard: EMC 2004/108/EC 5132 Standard : A 1 channel Emission and immunity ...... EN 61326-1 LVD 2006/95/EC ......... EN 61010-1 2 channels : 2 PELV/SELV ..........IEC 364-4-41 and EN 60742...
  • Page 14: Application

    Entrée / Alimentation du transmetteur....32 Sortie / Alimentation du PR-5132 ....32...
  • Page 15: Avertissements

    REUSE raccordement et débranchement de fils et recherche de pannes sur le module. Seule PR electronics SARL est autorisée à réparer le module et à remplacer les dis joncteurs. AVERTISSEMENT ! Il convient de monter l’appareil SYSTEM 5000 sur un rail DIN en se conformant à...
  • Page 16 Vous pouvez également vous adresser à PR vente conclu. electronics SARL, Zac du Chêne, Activillage, 4, allée des Sorbiers, F-69673 Bron Cedex (tél. : (0) 472 140 607) ou à PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Danemark (tél. :+45 86 37 26 77).
  • Page 17: Déclaration De Conformité

    En ouvrant la plaque avant, vous pouvez accéder au connecteur de programmation déclare que le produit suivant : (voir figure 3). Type : 5132 Nom : Répétiteur pour transmetteur 2-fils correspond aux directives et normes suivantes : La directive CEM (EMC) 2004/108/CE et les modifications subséquentes EN 61326-1 Pour une spécification du niveau de rendement acceptable CEM (EMC)
  • Page 18: Applications

    -20°C à +60°C APPLICATIONS : Spécifications communes : Le répétiteur PRetrans 5132 est utilisé pour créer une isolation galvanique dans Alimentation..........10...35 Vcc une boucle de courant (4...20 mA) entre un transmetteur 2-fils et, par exemple, un Vchute pour PR-5132 A ......< 4 Vcc automate programmable.
  • Page 19: Référence De Commande

    Sortie : Type Version Voies Gamme de mesure ........4...20 mA Rapport entrée / sortie ....... 1:1 5132 Standard : A 1 voie Limite de courant ........40 mA 2 voies Approbation GOST R : VNIIM, Cert. No.......... Ross DK.ME48.V01899 Agréments et homologations :...
  • Page 20: Application

    APPLICATION : 2-DRAHT- MESSUMFORMER-VERSTÄRKER PRetrans Typ 5132 API ou autres API ou autres +Valim. Entrée TEST INHALTSVERZEICHNIS Transmetteur CH 1 2-fils Warnung ........38 API ou autres Sicherheitsregeln .
  • Page 21: Warnung

    SPANNUNG Installation, Montage und Demontage von Leitungen. Fehlersuche im Modul. Reparaturen des Moduls und Austausch von Sicherungen dürfen nur von PR electronics A/S vorgenommen werden. WARNUNG Das System 5000 muss auf eine DIN-Schiene nach DIN 46277 montiert werden. Der Verbindungsstecker im SYSTEM 5000 ist an Eingangstermi- nale angeschlossen, in denen gefährliche Spannungen auftreten...
  • Page 22: Sicherheitsregeln

    Händler vor Ort Kontakt aufnehmen. Sie können aber auch direkt vereinbarungen existieren können. mit PR electronics GmbH, Bamlerstraße 92, D-45141 Essen, (Tel.: (0) 201 860 6660) oder mit PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Däne mark (Tel.
  • Page 23: Konformitätserklärung

    ZERLEGUNG DES SYSTEMS 5000 Als Hersteller bescheinigt Zunächst ist gefährliche Spannung von den Anschlussklemmen zu trennen. Das PR electronics A/S Modul wird von der DIN-Schiene gelöst, indem man den unteren Verschluss löst, wie in Abb. 1 dargestellt. Die Platine wird daraufhin herausgenommen, indem...
  • Page 24: Anwendung

    2-DRAHT- ELEKTRISCHE DATEN: MESSUMFORMER-VERSTÄRKER Umgebungstemperatur: -20°C bis +60°C • Verstärker für 2-Draht-Messumformer 4...20 mA Allgemeine Daten: • Isolierter Eingang / Ausgang (3,75 kVAC) Versorgungsspannung (VDC) ..... 10...35 VDC • Schleifengespeist 10...35 VDC UDrop Standard ......... < 4 VDC • Ein- oder Zweikanalversion Isolationsspannung Test / Betrieb ....
  • Page 25: Bestellangaben

    GOST R Zulassung: BESTELLANGABEN: 5132 VNIIM, Cert. No.......... Ross DK.ME48.V01899 Eingehaltene Richtlinien: Norm: Version Kanäle EMV 2004/108/EG Emission und Immunität ...... EN 61326-1 5132 Standard : A 1 Kanal LVD 2006/95/EG ......... EN 61010-1 PELV/SELV ..........IEC 364-4-41 und EN 60742 2 Kanäle...
  • Page 26: Anwendung

    ANWENDUNG: Betriebs- spannung Versorg. Eingang TEST 2-Draht- CH 1 Messumformer Betriebs- spannung Versorg. TEST Eingang 2-Draht- CH 2 Messumformer 5132...
  • Page 27 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digi- France tale signalbehandlingsmoduler til industriel automation. Vores PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr kompetenceområder omfatter: Isolation, Displays, Ex-interfaces, 4, allée des Sorbiers tel. +33 (0) 4 72 14 06 07 Temperatur samt Universal-moduler.

Table of Contents