Connector Panel Installation - Sony BKSI-2440 Series Installation Manual

Idc board
Table of Contents

Advertisement

Information for inserting slot
A. When the board uses for root controller
Insert this board into the No.1 slot.
It is necessary to install the one root controller board in the
one Server Management System (SMS).
n
The root controller BKSI-2440 is able to control the
multiple iDC boards in the one Server Management
System by the only one.
For that reason, the root controller board has only to install
in the one out of multiple SIU-80A/80 units which are
installed in the iDC boards.
There's no need to install the root controller board to the
other SIU-80A/80 units.
(Refer to "1-3-2. Connection of iDC Link".)
B. When the board uses for device controller
Insert this board into any slot No.2 to No.8.
1-4 (E)

1-2-2. Connector Panel Installation

Flow for installation
Start
Slot selection
Switch setting on board
Model label attachment
Connector panel installation (BKSI-2441/2042/2043/2044)
End
General information for installation
. The connector panels (BKSI-2441/2042/2043/2044) are
inserted into any slot No.1 to No.8 in the rear of SIU-
80A/80.
. Each connector panel is inserted into the slot with the
same number as the BKSI-2440 installed in the front of
SIU-80A/80.
. The model label supplied with the connector panel is
attached to the chassis to prevent the panel inserting into
the incorrect slot when the connector panel replacement
and others.
w
Do not install with the power on
Touching the power contact portion or the primary
winding circuit on the SIU-80A/80 may cause electric
shock. Turn off the power and unplug the power cord from
the outlet before installing.