Wireless converter intermediate plug
Disconnect the connection between the Radio Bus transmitter and the eNet actuator
o
Press the Prog button (3) of the gateway for longer than 4 seconds.
The status LED flashes after 4 seconds. The gateway is in programming mode for
approx. 1 minute.
o
Also switch all the eNet Bus actuators to be disconnected to programming mode (see eNet
actuator instructions).
o
Press the connected channel button on the Radio Bus transmitter for longer than one
second or the scene button for longer than three seconds.
The connection to the eNet actuator is disconnected. The LED of the actuator flashes
quickly.
The eNet actuator is disconnected. The actuator exits programming mode automatically.
Resetting the device to the factory setting
All the connections in the gateway between transmitters and actuators are disconnected.
Recommissioning must take place.
i Before resetting to the factory setting, disconnect connected Radio Bus actuators (see
Disconnecting the connection to the Radio Bus actuator). This ensures that setting up new
connections does not cause unintentional switching operations.
o
Press the Prog button for at least 20 seconds.
The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster.
o
Release the Prog button and press it once again within 10 seconds.
All the connections are disconnected. The status LED flashes more slowly for approx. 5
seconds.
5 Appendix

5.1 Technical data

Rated voltage
Mains frequency
Rated load current
Power consumption
Degree of protection
Ambient temperature
Dimensions W×H×D
Transmitting range in free field
Receiver category
32582112
10865123
Figure 6: Disconnecting
11.04.2017
AC 230 V ~
50 / 60 Hz
16 A (I
)
L
max. 1 W
IP 20
-5 ... +45 °C
57×127×78 mm
typ. 100 m
2
6/8