DJ-9520 Heat Exchanger Version
a. With the cam lever down to the open position, thread in the four (4) socket head cap
screws.
b. Attach the Valve Body Alignment Tool (P/N 7214835) to the Junction Box and Collar
and tighten the adjustment knob hand tight.
Cam Lever
WARNING!
Failure to use the Valve Body Alignment Tool may cause leakage, poor Heat
Exchanger performance, damage to the chamber, or poor dispense quality.
c. With the cam lever down to the open position, tighten the four (4) socket head cap screws
with a 2.5 mm hex wrench.
d. Remove the Junction Box to Valve Body Alignment Tool.
8. Reassemble the Fluid Chamber, Seat, Nozzle, and TCA. See
Wetted Parts
34
Collar
Figure 6-35 Junction Box to Valve Body Alignment
earlier in this section.
Adjustment
Knob
Junction Box
Assembling the DJ-9500 –
Maintenance and Service