Setup; Overview; Setting Up The Dj-9500 - Nordson ASYMTEK DispenseJet Series Owner's Manual

Table of Contents

Advertisement

5

Setup

Overview

This section describes the procedures required to setup the DJ-9500 for dispensing.
NOTE Refer to the Fluidmove User Guide for detailed instructions on software configuration.

Setting Up the DJ-9500

To setup the DJ-9500:
1. Make sure the DJ-9500 is completely assembled. See
for complete assembly and disassembly instructions.
NOTE An optional Magnetic Low Fluid Sensor Kit is available. The DJ-9500 uses P/N
2. Connect the Fluid Reservoir to the jet (Figure 5-1 through Figure 5-3).
3. Install the DJ-9500 as detailed in
4. Verify the fluid pressure is set correctly for your particular application. Adjust the Fluid
Pressure to 0-2 bar (0-40 psi), depending on the fluid viscosity.
5. Verify that "DJ-Series" is selected as the active valve configuration in the Fluidmove Setup
Valves Screen.
6. When using an Active Nozzle, verify that the Active Nozzle checkbox is selected in the
Fluidmove Valve Settings Screen.
7. If your valve has a body heater, verify the appropriate temperature control settings in the
Fluidmove Heater Control Window (Body Heater is run on the Valve 2 Heater Channel).
Allow 15 minutes for the temperature to stabilize.
WARNING!
Caution should be used if valve offsets are uncertain as the next step causes
automatic motion of the jet nozzle to pre-determined locations. A Valve Offsets
routine should be performed after a valve change and after a hardware change or
location adjustment.
8. Perform the appropriate Fluidmove setup routine. The setup routine purges the valve,
calibrates the nozzle to the camera offset, and verifies jet operation.
Setup
7201410 and it attaches to the syringe holder (P/N 7201394) using the two
screws provided. The DJ-9520 uses P/N MLFS and attaches directly to the
syringe.
Section 4 -
CAUTION!
Section 6 - Maintenance and Service
Installation.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dispensejet dj-9500Dispensejet dj-9520

Table of Contents