► Insert a filter bag in the dust container that
fulfils statutory requirements (see chapter
7.8
).
► Replace the top section [2-1] and close the
locking clips [2-2].
► Attach the cable holder to the rear of the
mobile dust extractor (see Fig. [3]).
► Only CTM 48 E LE EC: Insert the sealing
plug [1-1] on the panel (see Fig. [1] ).
► Connect the suction hose to the machine.
6.2
Switch on/off
► Insert the plug into an earthed socket.
CAUTION
Risk of injury from tools starting up unex
pectedly
► Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con
nected tool is switched off.
The switch [1-9] serves as an on/off switch.
Switch position "0"
Appliance socket [1-11] is disconnected from
the power, mobile dust extractor is switched
off.
"MAN" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-11] is connected to the
power, the mobile dust extractor starts when
the connected tool is switched on.
7 Settings
7.1
Adjusting the hose diameter (only CTM
48 E LE EC)
► Adjust the hose diameter adjuster [1-8] to
match the diameter of the connected hose.
The monitoring devices will measure
the air speed in the extractor hose
correctly as a result (see chapter
7.1
).
16
7.2
Connecting electric power tools
WARNING
Risk of injury
► Observe the maximum appliance socket
connected load (see chapter "Technical da
ta")
► Switch off the electric power tool.
► Connect the electric power tool to the appli
ance socket [1-11].
7.3
Connecting pneumatic tools
WARNING
Risk of injury
► Switch off the air tool.
With the compressed air module [1-3], the au
tomatic switch-on function for the mobile dust
extractor also works in conjunction with air
tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lubri
cates the compressed air and enables an ad
justment of the air pressure. An IAS adapter
(454757) is available to connect Festool air tools
to the IAS system.
The operating pressure of the tool must be 6
bar for the automatic switch-on unit to function
correctly.
7.4
Connecting the energy box
The connection for the energy box (EAA) [1-4]
allows you to connect the mobile dust extractor
with the EAA in order to couple the automatic
switch-on unit on the mobile dust extractor with
the equivalent unit on the EAA.
7.5
Adjusting the suction power
► Use the rotary knob [1-10].
7.6
Applying the brake
Folding out the black brake lever [1-15] pre
vents the mobile dust extractor from rolling. To
achieve this, lift the front end of the mobile dust
extractor slightly and push the black brake lev
er downwards until it latches into place. Push
the green lever [1-14] again to release.
7.7
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera
ture to prevent overheating.
English